TBA Protective Solutions ECP 537 Static Dissipative High Temperature Paint

ECP 537 static dissipative high-temperature paint is a single component static dissipative silicone/acrylic coating that provides excellent anti-static protection in addition to its anti-corrosion properties. Continuous heat resistance is provided up to 3500C. Used in areas where ESD (electrostatic discharge) is to be avoided.

Product Type: 1K (1 component) Coating

Features: Anti-Static, Corrosion Resistant, High Temperature Performance, Static-Dissipative

Application Area: Electrical Components

Application Method: Brush, Spray

Chemical Family: Acrylics & Acrylates, Mixtures & Blends

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Chemical Family
Product Type
Technologies
Product Families
Composition

Phenylmethyl polysiloxane resin/acrylic resin/conductive mineral additive/titanium dioxide.

Features & Benefits

Ready-to-Use Product Features
Overview
ECP 537 Static Dissipative High Temperature Paint

Applications & Uses

Markets
Applications
Application Area
Application Method
Applications

Oven interiors, flow solder machines etc.

Properties

Physical Properties
ValueUnitsTest Method / Conditions
Coverageapprox. 4 - 6sq.mtrs/litre-
Drying Time (Air, Touch Dry)1hours-
Shelf Life6 Months--
Specific Gravity1.3g/cm³-
Stoving (at 220°C)10 - 15minutes-
Surface Resistivity10⁸ohms/sqASTM D257

Regulatory & Compliance

Certifications & Compliance

Technical Details & Test Data

Application

Surface preparation: All contaminants including mold release, grease and dirt must be removed.  A suitable primer may be necessary on certain substrates.

Mixing: Some settling may occur in the can so care must be taken to mix in all solids.  Should any dilution be necessary ECP 537 thinners should be used.

Application: ECP 537 can be applied either by a conventional spray gun (40 - 50 psi pressure) or by brush coating.

Stoving: Allow parts to air dry for a minimum of 24 hours then oven cured at a temperature of 100 celsius for approximately 10 minutes.

Safety & Health

Precautions
  • Highly flammable. Keep away from heat, sparks and open flames. Keep all containers closed when not in use.
  • Use under well-ventilated conditions.  Personal respiratory protection should be worn under spraying conditions. Such deviced must be used in accordance with the manufacturer's instructions.
  • Avoid contact with skin. Wear protective gloves and clothing. Wash thoroughly with soap and water after use.  If accidentally swallowed seek medical advice.

Packaging & Availability

Packaging Type
Availability

ECP 537 is available in 5 and 20-liter cans.