Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Composite Materials Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
Properties
- Typical Properties
Value Units Test Method / Conditions Glow wire GWFI 960 °C IEC 695-2-1 Heat distortion temperature HDT min. 200 °C ISO 75 arc resistance min. 180 s ASTM D 495 Dielectric rigidity 18 KV/mm IEC 243 Linear Shrinkage 1, 0 % ISO 2577 Density 1, 75 g/cm3 ISO 1183 Rockwell hardness 80 Hrm ISO 2039-2 Surface resistivity 10^14 Ω IEC 93 Volume resistivity 10^14 Ω mm IEC 93 Water absorption max. 0,2 % ISO 62 Met. 1 Quantity of glass 33 % ISO 11667 Flexural strength 180 Mpa ISO 14125A Flexural modulus 10 Mpa ISO 14125A Impact strength (Charpy) 90 KJ/m2 ISO 179 - Flammability
Value Units Test Method / Conditions Flammability V0 (3,0) - -
Storage & Handling
- Handling and Storage
- Storage at 15-25°C, in dry ambient and out of direct sun light
- Molding time 40 s/mm
- Molding pressure 70 - 110 bar
- Molding temperature 140 – 160°C