Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Reinforcement Material
- Composite Materials Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
Properties
- Flame Rating
- Typical Properties
Value Units Test Method / Conditions Glow wire GWFI 960 °C IEC 695-2-1 Flexural strength 100 MPa ISO 14125A Impact strength (Charpy) 35 KJ/m2 ISO 179 Heat distortion temperature HDT min. 200 °C ISO 75 Flexural modulus 11 MPa ISO 14125A arc resistance min. 180 s ASTM D 495 Quantity of glass 25 % - Linear Shrinkage 0,1 % ISO 2577 Rockwell hardness 80 HRm ISO 2039-2 Dielectric rigidity 16 KV/mm IEC 243 Density 1,8 g/cm3 ISO 1183 Water absorption max. 0,2 % ISO 62 Met. 1 Surface resistivity 10^14 - - Volume resistivity 10^14 - - - Flammability
Value Units Test Method / Conditions Flammability V0 (3,0) - -
Regulatory & Compliance
Storage & Handling
- Handling and Storage
- Storage at 15-25°C, in dry ambient and out of direct sun light
- Molding time 30 s/mm
- Molding pressure 60 - 110 bar
- Molding temperature 140 - 160°C