Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Reinforcement Material
- Composite Materials Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
Properties
- Typical Properties
Value Units Test Method / Conditions Rockwell Hardness 80 Scale M ISO 2039-2 Glow wire GWFI 960 °C IEC 695-2-1 Heat distortion temperature HDT min. 200 °C ISO 75 Tracking resistance CTI 600 V IEC 112 Flexural strength 90 MPa ISO 14125A Flexural modulus 9.5 MPa ISO 14125A Impact strength (Charpy) 25 KJ/m2 ISO 179 arc resistance min. 180 s ASTM D 495 Quantity of glass 18 % ISO 11667 Linear Shrinkage 0,1 % ISO 2577 Water absorption 0,2 % ISO 62 Met. 1 Density 1,8 g/cm3 ISO 1183 Surface resistivity 10^14 - - Volume resistivity 10^14 - - - Flammability
Value Units Test Method / Conditions Flammability V0 (3,2) - -
Regulatory & Compliance
Storage & Handling
- Handling and Storage
- Storage in a dry place at 15-25°C, out of direct sunlight
- Molding time 30 s/mm
- Molding pressure 60 - 110 bar
- Molding temperature 140 - 160°C