Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Carrier
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Features & Benefits
- Extends the useful life of the roof.
- Resistant to dirt pick up.
- Resistant to asphalt staining, excellent “bleed through” resistance.
- By decreasing roof surface temperature, PolyBrite 71-HS can reduce energy costs.
- Fungal and algal resistant – even in high temperatures
- Offers excellent resistance to extended exposure to solar ultraviolet energy.
- Low VOC, non-flammable and presents minimal hazard to the applicator or the environment.
- Offers high tensile strength and elongation.
- Benefits
- Polyglass offers all the product components needed for these systems – one stop shop
- A variety of systems which can be used on new construction or tear off and replace roofs
- Offers excellent resistance to extended exposure to solar ultraviolet energy
- Can decrease the roof surface temperature, thereby reducing energy costs
- Superior tensile strength for a strong roof
- Easy to install, no kettle, no torch and no special tools or equipment needed other than a heavy roller
- Much safer than traditional hot asphalt BUR or torch down systems
- Should reduce the cost of insurance for the roofing contractor
- Low VOC and odor - presents minimal hazard to the applicator or the environment
- Resistant to dirt pick-up – easy to maintain
- Fungal and algal resistant
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Uses
- Functions as either a base or surface coating.
- Suitable for use on various aged smooth and granulated asphalt built-up and granulated polymer modified roof membranes, most metal roof systems, single-ply membranes (a primer may be required), concrete, exterior-grade plywood, SPF, rigid cover boards such as Dens-Deck® and Securock®. A substrate adhesion test is recommended prior to product application.
- Suitable for use on cementitious stucco, EIFS, and other masonry surfaces.
- Application Instruction
Surface Preparation
- All surfaces to receive coating must be clean, dry and free from any foreign matter such as dirt, oils, grease or other debris that could inhibit the adhesion capabilities of the newly installed products.
- Metal surfaces that display rusting or other oxidation, to be prepared with a grinder or wire brush as needed to remove surface contaminants.
- Visually inspect existing roof systems for conditions that may adversely affect adhesion of performance of newly installed products. Repair any visible deficiencies such as splitting, blistering, and buckling with PolyBrite 72 Premium Grade Elastomeric Flashing Compound or PolyBrite 73 Elastomeric Flashing Compound with StretchSpan Technology™ and PolyBrite Polyester Fabric.
- Repair all metal and non-metal flashings, edges, drains, valleys and through-roof penetrations.
- Do not apply to wet or visibly damp surfaces, or surfaces previously covered with coal tar based products or Kynar® finishes.
- Concrete surfaces cured with wax/resin based compounds can inhibit adhesion
Application
- Stir well prior to application. To field tint this product, please use a water-based, exterior-grade pigment.
- Apply with high pressure sprayer for best appearance and coverage, however the product may be applied by roller or brush applications.
- Apply at 24 wet mils (1.5 gallon per 100 square feet) per coat. Typical application conditions require two coats at 24 wet mils per coat. To minimize potential voids or pinholes in coating application, apply second coat perpendicular to the first.
- Allow coating to dry overnight prior to applying second coat.
- Apply only when ambient temperatures are 50°F and rising. Cold weather could result in uneven application and improper curing of product. Do not apply if there is a threat of inclement weather within 24 hours of application.
- Do not thin product. Do not heat outside of container. Do not apply at temperatures greater than 120°F.
- Prior to using this product on new cap sheets (smooth or granulated), it is recommended to wait 30 days for weathering.
Cleaning
- Clean equipment and overspray with water.
- Clean hands with waterless hand cleaner.
- Application tools and equipment can be cleaned with lukewarm water and soap, followed by a rinse of isopropanol, acetone, or Simple Green®. Recirculate through lines and gun until residual coating is removed.
- Do not use mineral spirits, xylene, toluene, or VMP & naptha solvents.
- Application Types
- Spray
- Brush
- Roll
Properties
- Color
- Typical Properties
Value Units Test Method / Conditions Viscosity 28000 - 58000 cP Brookfield 4d/5 RPM/77°F Solids (By Volume) 58 - 62 % ASTM D2697 Solids (By Weight) 68 - 72 % ASTM DI644 Tensile Strength 245 - 345 psi ASTM D2370 Elongation 230 - 335 % ASTM D2370 Accelerated Weathering (1000h) Pass - ASTM D4798 Fungi resistance (Rating) Pass - ASTM G21 VOC max. 20 g/l Calculated pH (Rating) 9.0 - Std Method Flash Point min. 212 °F PMCC Weight 10.5 - 11.5 lb/gal ASTM D1475
Regulatory & Compliance
- Applicable Standards
- Meets or exceeds the requirements of ASTM D6083, Type II Standard Specification for Liquid-Applied Acrylic Coating Used in Roofing
- UL Classified - File #R14571
- FM Approved
- ICC ESR-4038
- Can be used to comply with 2016 Title 24 Part 6 Cool Roof Requirements (White only)
- CRRC Listed (White only)
- Texas Department of Insurance
- Florida Building Code
- Miami-Dade County Product Control Approved
Technical Details & Test Data
- Compatible Substrates
BUR, Granulated Mod Bit, Most Metals, Concrete, Exterior Grade Plywood, Rigid Coverboards, SPUF, Single Ply Membranes (Primer may be required)
Packaging & Availability
- Packaging Type
- Packaging
- 4.75 Gallon (17.9 Liters) Pail
- 50 Gallon (189 Liters) Drum
- 275 Gallon (1039.5 Liters) Tote
Storage & Handling
- Storage & Handling
- All containers should be sealed when not in use.
- Keep from freezing.
- Store between 40°F and 100°F.
- Observe normal safeguards for storing and handling of this product prior to and during application.
- Shelf Life
Shelf life is 18 months if stored in original unopened containers.