Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Highlights
MICOROX® 145 SEALER is a two component 100% solids epoxy sealer designed to offer outstanding chemical resistance.
Applications & Uses
- Markets
- Applications
- Compatible Substrates & Surfaces
- Applications
145 is used to enhance the chemical resistance and increase cleanability of MICOROX®FLOORING SYSTEMS and as a stand alone floor coating for extreme chemical service. On concrete surfaces we recommend using a good penetrating primer such as:
- MICOROX® 103 PRIMER: a two component deep penetrating water reducible epoxy primer.
- Waterproofing : Where waterproofíng membrane is required use MICORTHANE™6-75P ELASTOMERIC PRIMER per application instructions.
Coverage : 150 sq.ft./gal. (depending upon the surface coated)
- Areas of Application
Containment Areas, Floors, Trenches, Pits. Pump Pads, Sumps, Stock Chests, Wastewater Vessels, etc.
- Surface Preparation
- When used as a topcoat for MIcOROX®FLOORING SYSTEMS: Grind the surface with medium stones and vacuum to remove resulting dust.
- When applied as a concrete coating: The surface to be coated must be sound and free of dirt, grease, oil, old coatings. Substrate must be exposed by acid etch or mechanical means.
- Application
- 145 SEALER is extremely easy to install and may be applied by contractors or plant personnel.
- On concrete surfaces MIcOROX®103 makes an excellent primer. Apply the primer in a thin even film. Consult the primer data shets for mixing instructions.
- Mix 145 SEALER by combining one premeasured container of resin with one premeasured container of hardener. Mix thoroughly with a drill-stirrer. components to disperse any settled fillersor pigments. Materials should be mixed for approximately two minutes. No induction time is required. The material may be applied immediately.
- Premix Apply the material by squeegee, roller or brush. Apply in a even 10-20 mils thickness. If a second coat is being applied, timing is important. Allow the first coat to cure for 12 hours. If the second coat cannot be applied within 48 hours., the surface must be sanded before recoating.
- Temperature Limitations
During the installation and cure of 145 Sealer surface temperatures of 60° F- 90° F. are recommended.
Properties
- Physical Properties
Value Units Test Method / Conditions Compressive Strength 9000.0 psi ASTMD-695-77 Compressive Modulus 1.95 x 10⁵ psi ASTMD-695-77 Tensile Strength 6600.0 psi ASTM D638-77a Tensile Modulus 3.4 X 10⁴ psi ASTM D-638-77a Tensile Elongation 16.0 % ASTM D 638-77a Flexural Strength 9900.0 psi ASTM D-790-71 Flexural Modulus 3.7X 10³ psi ASTM D-790-71 Hardness 80 - 85 Shore D ASTM D-2240/Durometer Bond Strength max. 400 psi - Abrasion Resistance 31.0 gm /1000 revolutions - Water Absorption 0.1 % ASTM C-413
Technical Details & Test Data
- Cure
145 SEALER is ready for foot traffic in 12 hours and ready for light wheeled traffic in 24 hours at 77°F. Complete cure may require 24 to 72 hours depending on temperature.
Cure Rate : Allow
- 18 hrs for foot traffic
- 24 hrs for light traffic
Safety & Health
- Precautions
Contact with liquids Part A and B can cause irritation. Wear protective clothing. Cover hands with protective cream and/or gloves. Wear chemical splash goggles. Use only with adequate ventilation.
Packaging & Availability
- Packaging
145 SEALER is packaged in pre- proportioned units based on gallon quantities
- Availability
Available in Clear and 14 basic colors. Custom colors upon request.