LUBE-LOK® 2396

Lube-Lok® 2396 is a low VOC, thermally cured, MoS2/Graphite based solid film lubricant which utilizes a silicate binder system. This coating provides excellent thermal stability, very good chemical resistance, lead free, and performs best in higher load carrying applications. Lube-Lok® 2396 is approved/qualified to many aerospace and industrial specification.

Brand: LUBE-LOK (3 products)

Product Type: Dry Lubricants, Industrial Lubricants

Application Area: Bearings, Gears

Features: Chemical Resistant, Good Thermal Stability, High Coefficient of Friction, Low VOC, Wear Resistant

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features & Benefits
  • Excellent thermal stability.
  • Excellent coefficient of friction.
  • Very good wear life.
  • Ideal for higher load carrying applications.

Applications & Uses

Markets
Applications
Application Area
Application Method
Markets
  • Medical
  • Semiconductor
  • Fabricated Metal Parts
  • Fasteners
Typical Applications
  • Specialty fasteners.
  • Bushings, shafts, and splines.
  • Bearing guides and sleeves.
  • Gears, cams and followers.
Suggested Pretreatment

Grit Blast

Suggested Application Method

Dip Spin, Brush or Spray

Dilution/Cleanup Solvent

Deionized Water

Cure Cycle

2 hour at 180°F, then 2 hour at 400°F.

Properties

Physical Properties
ValueUnitsTest Method / Conditions
BinderSilicate--
CarrierWater Borne--
AppearanceLight Gray Matte Finish--
Density13.1 - 14.1Ib/gal-
Lubricating SolidMoS₂, Graphite--
Solids (By Weight)51 - 55%-
Theoretical Coverage (0.5 mils)936.0ft²/gal-
VOC Content0.0grams/liter-
Typical Properties
ValueUnitsTest Method / Conditions
Abrasion ResistanceFair-ASTM D-4060
Coefficient of Friction0.02 - 0.04-ASTM D2714
Corrosion Resistance Test Panelmax. 48hoursASTM B117
Corrosion Resistance Test Panel Coating Method (Grit Blasted Steel Panel)0.8mil-
Dilution RatioAs needed with Deionized Water--
Dry Film Thickness0.2 - 1.4mils-
Load Carrying Capacitymax. 100000psiASTM D2625, Method B
Operating Temperature Range-300 - 750--
Wear Lifemin. 60minutesASTM D2625, Method A
Chemical Resistance
ValueUnitsTest Method / Conditions
AcetonePass-ASTM D-2510, Method C
Anti-Icing FluidsPass-ASTM D-2510, Method C
DiethanolaminePass-ASTM D-2510, Method C
Distilled WaterNot Recommended-ASTM D-2510, Method C
Hydraulic FluidsPass-ASTM D-2510, Method C
Hydrochloric Acid (10%)Not Recommended-ASTM D-2510, Method C
Isopropyl Alcohol or Ethyl AlcoholPass-ASTM D-2510, Method C
Jet Fuels (JP-4)Pass-ASTM D-2510, Method C
Mineral Spirits or Paint ThinnerPass-ASTM D-2510, Method C
Skydrol 500 (room temperature)Not Recommended-ASTM D-2510, Method C
Sodium Hydroxide (10%)Not Recommended-ASTM D-2510, Method C
ToluenePass-ASTM D-2510, Method C
TrichloroethylenePass-ASTM D-2510, Method C

Packaging & Availability

Packaging Type
Packaging

Lube-Lok 2396 is available in gallon, quart, and 5-gallon pails.

Storage & Handling

Shelf Life & Storage

One year from date of shipment, stored in a factory sealed container between the temperatures, 40°F to 100°F. Coatings are thermally stable, but we do not recommend prolonged exposure outside of the specified temperature range listed above.