EVERLUBE® 9002

Everlube® 9002 is a low VOC MoS2 based solid film lubricant with a high molecular weight epoxy binder system. This coating provides excellent wear life, abrasion resistance, good chemical resistance, and performs the best in higher load carrying applications. Everlube® 9002 is approved/qualified to many aerospace and industrial specification.

Brand: EVERLUBE (12 products)

Product Type: Dry Lubricants, Industrial Lubricants

Features: Chemical Resistant, Corrosion Resistant, Good Abrasion Resistance, High Molecular Weight, Low VOC, Wear Resistant

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features & Benefits
  • Excellent wear life
  • Very good chemical resistance.
  • Excellent abrasion resistance.
  • Lead free

Applications & Uses

Markets
Applications
Application Method
Markets
  • Aerospace/Defense
  • Fasteners
  • Industrial Machinery & Equipment
  • Mechanical Components
Typical Applications
  • Virtually all fasteners.
  • Bearing and cams.
  • Gears and splines.
  • Engine ring seals.
Suggested Pretreatment

Grit Blast and/or Phosphate

Suggested Application Method

Dip Spin, Brush or Spray

Dilution/Cleanup Solvent

May be thinned with Deionized Water less than 10% by volume.

Cure Cycle (Recommended)

1 hour 15 minutes at 400°F (recommended) or 2 hours at 300°F (for substrates that cannot take recommended cure).

Properties

Physical Properties
ValueUnitsTest Method / Conditions
BinderHigh Molecular Weight Epoxy--
CarrierWater Based--
AppearanceGray / Dark Gray Matte Finish--
Density10.4 - 11.4Ib/gal-
Flash Pointmin. 200--
Lubricating SolidMoS₂--
Solids (By Weight)40 - 44%-
Theoretical Coverage (0.5 mils)698.0ft²/gal-
VOC Content183.0grams/liter-
Typical Properties
ValueUnitsTest Method / Conditions
Abrasion ResistanceExcellent-ASTM D-4060
Coefficient of Friction0.04 - 0.06-ASTM D2714
Corrosion Resistance Test Panel (5% Neutral Salt Spray)min. 100hoursASTM B117
Corrosion Resistance Test Panel Coating Method (Grit Blasted Steel Panel)0.8mil-
Dilution Ratio (Product to Diluent)0 to 9:1--
Dry Film Thickness0.2 - 0.5mils-
Load Carrying Capacitymin. 250000psiASTM D2625, Method B
Operating Temperature Range-100 - 400°F-
Wear Lifemin. 450minutesASTM D2625, Method A
Chemical Resistance
ValueUnitsTest Method / Conditions
AcetonePass-ASTM D-2510, Method C
Anti-Icing FluidsPass-ASTM D-2510, Method C
DiethanolaminePass-ASTM D-2510, Method C
Distilled WaterPass-ASTM D-2510, Method C
Hydraulic FluidsPass-ASTM D-2510, Method C
Hydrochloric Acid (10%)Pass-ASTM D-2510, Method C
Isopropyl Alcohol or Ethyl AlcoholPass-ASTM D-2510, Method C
Jet Fuels (JP-4)Pass-ASTM D-2510, Method C
Mineral Spirits or Paint ThinnerPass-ASTM D-2510, Method C
Skydrol 500Pass-ASTM D-2510, Method C
Sodium Hydroxide (10%)Pass-ASTM D-2510, Method C
ToluenePass-ASTM D-2510, Method C
TrichloroethylenePass-ASTM D-2510, Method C

Packaging & Availability

Packaging Type
Packaging

Everlube 9002 is available is gallon, 5-gallon pail, and quart.

Storage & Handling

Shelf Life & Storage

One year from date of shipment, stored in a factory sealed container between the temperatures, 40°F to 100°F. Coatings are thermally stable, but we do not recommend prolonged exposure outside of the specified temperature range listed above.