EVERLUBE® 9001

Everlube® 9001 is a thermally cured, low VOC MoS2/Graphite based solid film lubricant with a high molecular weight epoxy binder system. This coating provides excellent abrasion resistance, very good chemical resistance, good wear life, and performs best in higher load carrying applications. Everlube® 9001 is approved/qualified to many aerospace and industrial specification.

Brand: EVERLUBE (12 products)

Product Type: Dry Lubricants, Industrial Lubricants, Lubricant

Application Area: Medical Devices

Features: Chemical Resistant, Corrosion Resistant, Good Abrasion Resistance, High Molecular Weight, Low VOC, Wear Resistant

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features & Benefits
  • Excellent abrasion resistance.
  • Very good chemical resistance.
  • Good wear life.
  • Ideal for higher load carrying applications.

Applications & Uses

Markets
Applications
Application Area
Application Method
Markets
  • Aerospace/Defense
  • Medical
  • Industrial Machinery & Equipment
  • Mechanical Components
Typical Applications
  • Virtually all fasteners.
  • Bearing and cams.
  • Gears and splines.
  • Engine ring seals.
Suggested Pretreatment

Grit Blast and/or Phosphate

Suggested Application Method

Dip Spin / Spray

Dilution/Cleanup Solvent

May be thinned with Deionized Water less than 10% by volume.

Cure Cycle

1 hour at 375°F ± 25°F.

Properties

Physical Properties
ValueUnitsTest Method / Conditions
BinderHigh Molecular Weight Epoxy--
CarrierWater Based--
AppearanceGray / Black Matte Finish--
Density9.5 - 10.5Ib/gal-
Flash Pointmin. 200--
Lubricating SolidMoS₂, Graphite--
Solids (By Weight)33 - 39%-
Theoretical Coverage (0.5 mils)764.0ft²/gal-
VOC Content175.0grams/liter-
Typical Properties
ValueUnitsTest Method / Conditions
Abrasion ResistanceExcellent-ASTM D-4060
Coefficient of Friction0.02 - 0.04-ASTM D2714
Corrosion Resistance Test Panel (5% Neutral Salt Spray)max. 100hoursASTM B117
Corrosion Resistance Test Panel Coating Method (Grit Blasted Steel Panel)0.8mil-
Dilution Ratio (Product to Solvent)0 to 9:1--
Dry Film Thickness0.2 - 0.5mils-
Load Carrying Capacitymax. 100000psiASTM D2625, Method B
Operating Temperature Range-100 - 400°F-
Wear Life120.0minutesASTM D2625, Method A
Chemical Resistance
ValueUnitsTest Method / Conditions
AcetonePass-ASTM D-2510, Method C
Anti-Icing FluidsPass-ASTM D-2510, Method C
Cleaning Compound (MIL-C-372)Pass-ASTM D-2510, Method C
DiethanolaminePass-ASTM D-2510, Method C
Distilled WaterPass-ASTM D-2510, Method C
Freon TF (MIL-C-81302)Pass-ASTM D-2510, Method C
Hydraulic FluidsPass-ASTM D-2510, Method C
Hydrochloric Acid (10%)Pass-ASTM D-2510, Method C
Isopropyl Alcohol or Ethyl AlcoholPass-ASTM D-2510, Method C
Jet Fuels (JP-4)Pass-ASTM D-2510, Method C
Lubricant/Cleaner (MIL-L-63460)Pass-ASTM D-2510, Method C
Lubricating Oil (MIL-L-14107)Pass-ASTM D-2510, Method C
Lubricating Oil (MIL-L-46000)Pass-ASTM D-2510, Method C
Mineral Spirits or Paint ThinnerPass-ASTM D-2510, Method C
Reagent (H20)Pass-ASTM D-2510, Method C
Sea WaterPass-ASTM D-2510, Method C
Silicone Damping Fluid (VV-D-1078)Pass-ASTM D-2510, Method C
Skydrol 500Pass-ASTM D-2510, Method C
Sodium Hydroxide (10%)Pass-ASTM D-2510, Method C
Synthetic Hydraulic Fluids (MIL-H-83282)Pass-ASTM D-2510, Method C
Synthetic Lube Oil (MIL-L-23699)Pass-ASTM D-2510, Method C
Synthetic Turbine Lube Oil (Mil-L-7808)Pass-ASTM D-2510, Method C
ToluenePass-ASTM D-2510, Method C
TrichloroethylenePass-ASTM D-2510, Method C

Packaging & Availability

Packaging Type
Packaging

Everlube 9001 is available is gallon, 5-gallon pail, and quart.

Storage & Handling

Shelf Life & Storage

One year from date of shipment, stored in a factory sealed container between the temperatures, 40°F to 100°F. Coatings are thermally stable, but we do not recommend prolonged exposure outside of the specified temperature range listed above.