Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Features & Benefits
- Excellent thermal stability.
- Excellent stability in vacuum.
- Good wear life.
- Ideal for higher load carrying applications.
Applications & Uses
- Markets
- Applications
- Application Method
- Markets
- Aerospace/Defense
- Fasteners
- Mechanical Components
- Chemical Processing
- Typical Applications
- Bearing guides and races.
- Threaded connectors and disconnects.
- Bushings, rotary joints, and cams.
- Rings and Seals.
- Suggested Pretreatment
Grit Blast
- Suggested Application Method
Dip Spin / Spray
- Dilution/Cleanup Solvent
May be thinned with Deionized Water less than 10% by volume.
- Cure Cycle
2 hours at 175°F then 2 hours at 400°F.
Properties
- Physical Properties
Value Units Test Method / Conditions Binder Sodium Silicate - - Carrier Water Borne - - Appearance Bluish-Black Finish - - Density 10.4 - 11.4 Ib/gal - Lubricating Solid MoS₂ - - Solids (By Weight) 29.5 - 33.5 % - Theoretical Coverage (0.5 mils) 320.0 ft²/gal - VOC Content 0.0 grams/liter - - Typical Properties
Value Units Test Method / Conditions Abrasion Resistance Fair - ASTM D-4060 Coefficient of Friction 0.04 - 0.06 - ASTM D2714 Corrosion Resistance Test Panel 24 - 72 hours ASTM B117 Corrosion Resistance Test Panel Coating Method (Grit Blasted Steel Panel) 0.5 mil - Dilution Ratio (By Volume) max.10 % - Dry Film Thickness 0.3 - 1 mils - Load Carrying Capacity min. 250000 psi ASTM D2625, Method B Operating Temperature Range -365 - 750 °F - Wear Life min. 30 minutes ASTM D2625, Method A - Chemical Resistance
Value Units Test Method / Conditions Acetone Pass - ASTM D-2510, Method C Anti-Icing Fluids Pass - ASTM D-2510, Method C Diethanolamine Pass - ASTM D-2510, Method C Distilled Water Not Recommended - ASTM D-2510, Method C Hydraulic Fluids Pass - ASTM D-2510, Method C Hydrochloric Acid (10%) Not Recommended - ASTM D-2510, Method C Isopropyl Alcohol or Ethyl Alcohol Pass - ASTM D-2510, Method C Jet Fuels (JP-4) Pass - ASTM D-2510, Method C Mineral Spirits or Paint Thinner Pass - ASTM D-2510, Method C Skydrol 500 Not Recommended - ASTM D-2510, Method C Sodium Hydroxide (10%) Not Recommended - ASTM D-2510, Method C Toluene Pass - ASTM D-2510, Method C Trichloroethylene Pass - ASTM D-2510, Method C
Packaging & Availability
- Packaging Type
- Packaging
Everlube 812 is available is gallon, 5-gallon pail, and quart.
Storage & Handling
- Shelf Life & Storage
One year from date of shipment, stored in a factory sealed container between the temperatures, 40°F to 100°F. Coatings are thermally stable, but we do not recommend prolonged exposure outside of the specified temperature range listed above.