Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Advantages
Easy to handle and place No mixing ratios to measure Packaged in pre-measured containers Grouts machinery in final aligned position Low exotherm for deeper pours High early strength High impact strength Superior resistance to fatigue Resistance to many chemicals Impervious to oil Moisture insensitive Strong bond to metal and concrete Unaffected by weathering and freeze/thaw cycling
Applications & Uses
- Applications
- Compatible Substrates & Surfaces
- Mixing
Armor Plate 999MP is packaged as a three-part, premeasured system of Resin (A), Cure (B), and Aggregate (C). Resin and cure must be thoroughly mixed before aggregate is added. DO NOT add aggregate before resin and cure are properly mixed Mix the AP 999MP according to the following instructions:
1 Add Armor Plate 999MP Cure (part B) to Armor Plate 999MP Resin (part A). DO NOT add Aggregate at this time. 2 Mix Resin and Cure thoroughly for at least 2 minutes. Use an electric mixing blade, a horizontal agitator, or other mechanical equipment suited for producing homogenous mix. 3 Pour the completely mixed AP 999MP Resin and Cure into a concrete or mortar mixer. 4 Add one-half of the AP 999MP Aggregate (part C) and mix until it is thoroughly wetted. 5 Add the remainder of the Aggregate and mix until all of the aggregate is thoroughly wetted. 6 For smaller batches use a 3/4″ drill and mix one (1) gallon with 50 lbs of Aggregate (part C). 7 To increase flow, solvent approved by Wil-Cor, Inc. may be added.- Surface Preparation
All surfaces (grout bed, sole plates) should be smooth, clean and free of oil. The mainframe surface should be smooth, bright metal. Sharp frets should be ground smooth and any voids should be filled with Armor Plate 990 Epoxy Putty.
- Application
Armor Plate 999MP cures quicker than other grouts, but the cure is thermally gentle. This allows thick pours to be made without causing the stress cracks often associated with a hot-curing epoxy grout. Armor Plate 999MP may be used in any thickness greater than 1/2 inch (12mm)
however, individual pours should generally not exceed 12 inches (31 cm) in thickness and 5.0 feet (1.1 m) in length.Cure and Working Times Temperature (°
F)100 95 90 85 80 75 70 65 60 Cure Time (hrs)
10 12 15 18 24 30 36 46 56 Working Time (min)
30 35 40 45 50 55 60 70 80 - Limitations
Do not use Armor Plate 999MP is base of the operating equipment to be grouted exceeds 150 °F on a continuous basis. If temperatures are greater, use Armor Plate 999 Heavy Equipment Grout.
Properties
- Typical Properties
Value | Units | Test Method / Conditions | |
Color | Gray | - | - |
Viscosity | Flowable Grout | - | - |
Pot Life (65 °F) | 5.0 | hours | - |
Pot Life (77 °F) | 3.5 | hours | - |
Pot Life (90 °F) | 2.0 | hours | - |
Pour Depth (one lift) | 12.0 | inches | - |
Maximum Operating Temperature | 150.0 | °F | - |
Shrinkage | 0.0005 | in/in | ASTM C-531 |
Compressive Strength (Ambient Temperature) | 11800.0 | psi | ASTM C-579/Method B |
Compressive Strength (Tensile Strength (ASTM C-307-61)) | 2410.0 | psi | ASTM C-579/Method B |
Compressive Strength (Flexural Strength (ASTM D-790)) | 4680.0 | psi | ASTM C-579/Method B |
Technical Details & Test Data
- Chemical Resistance
Armor Plate 999MP is resistant to alkalies, dilute acids, oils, salts and water. Contact the Wil-Cor, Inc. Technical Department for chemical resistance in specific service conditions.
Safety & Health
- Caution
Armor Plate 999MP is a low toxicity system, but allergic reaction may occur in some persons. Use Armor Plate 999MP in well ventilated areas and avoid breathing fumes or aggregate dust. Avoid skin contact if possible. Gloves and other protective equipment are recommended. Use soap and water to thoroughly clean contaminated areas of the body. In case of eye contact, thoroughly flush the eyes with water and seek immediate medical attention.
Packaging & Availability
- Packaging
Armor Plate 999MP is available in a pre-measured unit containing Component A (Resin), Component B (Cure/Hardener) and Component C (Aggregate), for a total weight per unit of 242 lbs. This unit yields 2.0 cu. ft. of mixed material.
Storage & Handling
- Shelf Life
Armor Plate 999MP grout components must be kept dry. Both the epoxy liquid and aggregate must be stored in a dry shelter. Freezing will not harm any of the Armor Plate 999MP components. Parts A, B and C may be stored in sub-zero conditions, such as occur at Prudhoe Bay, Alaska. Both component A and B have a minimum 1 year in tightly sealed containers and Component C has an indefinite shelf life if kept dry.