Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Polymer Name
- Reinforcement Form
- Reinforcement Material
- Composite Materials Functions
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Composites End Use
- What is Grade 10G/42 used for?
- These high-performance materials are used for a very wIde variety of applications where high strength, rigidity dimensional stability and electrical performance are required.
- Applications such as insulation in large turbine generators, components for cryogenic superconducting magnets, high-strength bolt insulation in structures, jigs for electro-chemical machining and structural insulation for high peformance electronic equipment, these are typical of the many uses to which this material is put.
- However, due to the abrasive nature of the high glass fiber content, epoxy glass grades are not normally selected for wearing or bearing applications.
Properties
- Color
- Physical Properties
Value | Units | Test Method / Conditions | |
Cross Breaking Strength | 490.0 | MPa | - |
Cross Breaking Strength (150°C, After 1 hour) | 350.0 | MPa | - |
Impact Strength (Notched, Charpy) | 60.0 | kJ/m² | - |
Compressive Strength (Flatwise) | 415.0 | MPa | - |
Compressive Strength (Edgewise) | 300.0 | MPa | - |
Water Absorption (1.6mm Thick) | 5.0 | mg | - |
Water Absorption (3mm Thick) | 7.0 | mg | - |
Water Absorption (6mm Thick) | 10.0 | mg | - |
Water Absorption (12mm Thick) | 15.0 | mg | - |
Electric Strength (Flatwise in Oil, 90°C, 1.6mm Thick) | 17.0 | MV/m | - |
Electric Strength (Flatwise in Oil, 90°C, 3mm Thick) | 15.0 | MV/m | - |
Electric Strength (Flatwise in Oil, 90°C, 6mm Thick) | 12.0 | MV/m | - |
Electric strength (Edgewise in Oil, 90°C) | 70.0 | kV | - |
Insulation Resistance (After Immersion in Water) | 5 × 10¹⁰ | ohms | - |
Relative Density | 1.9 | - | - |
Loss Tangent (1MHz) | 0.017 | - | - |
Permittivity (1MHz) | 5.2 | - | - |
Comparative Tracking Index | 290.0 | - | - |
Working Temperature (Continuous) | max. 140 | °C | - |
Working Temperature (Intermittent) | max. 155 | °C | - |
Thermal Classification | Class F | - | - |
Thermal Conductivity (Through Laminae) | 0.45 | W/mK | - |
Thermal Expansion (Plane of Laminae) | 1.2 × 10⁻⁵ | /K | - |
Regulatory & Compliance
- Specifications
British Standards Current Standards Recent Standards (Now Obsolete) Grade 10G/42 Sheet BS EN 60893-3-2 Type EP GC 203 BS 3953 Type EP-5
NEMA* - Grade 10GI40 Sheet & Rod - NEMA L-1-1983 Type G11
*Testing and certification to these standards is subject to special enquiry. Standard quality testing is to British Standards.
Packaging & Availability
- Types Available
Types Availabe Sheets Rods Tubes Other Sections Tufnol Grade 10G/42 - Natural Color Yes No No No