Properties

Mechanical Properties
ValueUnitsTest Method / Conditions
Tensile Strength22MPaISO 527
Charpy Notched Impact Strength (at 23°C)5kJ/m2ISO 179-1/1eA
Hardness75Shore DISO 7619-1
Hardness75Shore DISO 868
Charpy Unnotched Impact Strength (at 23°C)NBkJ/m2ISO 179-1/1eU
Yield stress28MPaISO 527
Strain at break100%ISO 527
Elongation at Breakmin. 100%ISO 527-2/1A
Flexural modulus, 23°2100MPaISO 178
Flexural Modulus2100MPaISO 178
Izod Notched Impact Strength5.5kJ/m2ISO 180/1A
Charpy notched impact strength (+23°)5kJ/m2ISO 179/1eA
Charpy impact strength (+23°)NkJ/m2ISO 179/1eU
Stress at Break22MPaISO 527-2/1A
Stress at Yield Point28MPaISO 527-2/1A
Physical Properties
ValueUnitsTest Method / Conditions
Melt Volume Flow Rate - MVR (230°C/2.16 kg)22cm3/10 minISO 1133
Density1150kg/m3ISO 1183
Thermal Properties
ValueUnitsTest Method / Conditions
Temperature of deflection under load (1.80 Mpa)65°CISO 75-1/-2
Melting temperature (10°C/min)167°CISO 11357-1/-3
Heat Deflection Temperature65°CISO 75-2/Af
Melting Point165/168°CISO 11357-3
Vicat Softening Point153°CISO 306/A50
Vicat softening temperature153°CISO 306
Electrical Properties
ValueUnitsTest Method / Conditions
CTImin. 600VCEI 60112
Physico-Chemical Properties
ValueUnitsTest Method / Conditions
Density1.15g/cm3ISO 1183-1
MVI (at 230°C-2.16Kg)20cm3/10minISO 1133-1
Fire Resistance
ValueUnitsTest Method / Conditions
Falling Ball Test138°CCEI 60695-10-2
Incandescent Glow Wire Flammability Test (2mm)750°CCEI 60695-2-12
Limit Oxygen Index18%ISO 4589-2

Regulatory & Compliance

Certifications & Compliance

Technical Details & Test Data

Note
  • The LOI measures are obtained through standard specimens of type I, with ignition of type A.
  • The values indicated above have been realized with standard specimens which are conditionned according to ISO 291. These datas must be considered as indicative values, but in no case as minimum values. Moreover, the design of the mold/die, the processing conditions and the color may have an impact on the properties.