Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Carrier
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Advantages
- USDA/FDA Compliant
- Water based
- Moisture Tolerant
- Chemical Resistant
- Long Pot Life
- Medium Gloss
- Very Durable
- Easy to Use
- Very Fast Drying
- No Induction Time
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Uses
- EC-11 is designed to be used on concrete, metal, masonry or wood where a tough, chemical-resistant finish is needed.
- EC-11 is recommended for use as a medium-duty concrete sealer for interior floors.
- EC11 may also be used as a primer under many Westcoat Systems.
- Inspection
- The surface must be structurally sound, clean, dry and free of grease, paint, oil, dust, curing agents, laitance or any foreign material that will prevent proper adhesion.
- The concrete should be at least 2,500 PSI and porous or rough enough to allow the product to soak in.
- A minimum of 28 days curing time is required on all concrete.
- Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure.
- Preparation
- Pre-cut and clean all cracks and joints with a concrete diamond blade to at least ¼ x ¼ inch.
- Prepare concrete to a profile equal to CSP 3-4 as specified by ICRI.
- Methods may vary according to the condition and hardness of the concrete.
- Other factors include the forecasted use of the surface and the environment in which it is to be installed.
- When preparing the surface use caution when shot blasting, scarifying too aggressively, leaving grind marks or grinding too smooth.
- Moisture
- All concrete should be tested for moisture before applying a seamless coating.
- If moisture emissions exceed 5 lbs/1000 square feet/24 hours (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.
- Mixing
- Premix each component separately.
- For color consistency, box all part A’s. In a clean bucket, mix 2 parts A with 1 part B (by volume) of EC-11.
- Mix thoroughly with a low speed (400-600 rpm) drill motor for 3-4 minutes.
- Make sure to scrape the sides and bottom of the container during mixing.
- After mixing is completed, remove material from container within 5 minutes, as epoxy will begin to generate heat.
- Spread immediately onto the floor.
- As product is spread out, you will have longer working time (10-15 minutes at 70°F).
- Thinning
- Thin with water, up to 50%
- Amount will vary depending on use.
- Coverage
Will vary depending on the mil thickness applied and the porosity and texture of the surface, but in general, EC-11 will cover approximately 300-600 square feet per gallon as a primer, coating or sealer.
- Applying Product
- As a primer, spray or squeegee and backroll thinned EC-11 onto the surface.
- Primer coat should be applied evenly and worked into the surface to help seal and avoid pinholes.
- When thinned, apply EC-11 at a maximum of 5 mils.
- Do not allow material to puddle.
- As a coating or sealer, apply EC-11 within 24 hours after the primer coat.
- Immediately after mixing, spread a strip of material onto the surface along the edges, where it will be “cut in” using a brush.
- Pour the remaining material near the “cut in” area and spread evenly using a trowel or squeegee and back roll using a 1/4 inch nap non-shedding roller.
- Depending on the look, thickness, chemical and abrasion resistance desired, 1 to 2 coats may be applied.
- Dry Time
- You may re-coat as soon as the surface is dry to the touch in 1 to 4 hours, but no later than 24 hours.
- Light foot traffic may be permitted in 6 hours, normal traffic in 24 hours and vehicle traffic in 72 hours.
- All times are based on average temperature of 70F degrees and 50% humidity.
- Cooler temperatures will increase drying time.
- Clean Up
- Uncured material should be removed with soap and warm water.
- Cured material should be removed mechanically or with an environmentally-safe solvent.
- Limitations
- This product is designed for professional use only.
- Be sure to measure and mix properly. Be aware of the pot life of mixed epoxy.
- Do not apply when temperatures are below 50°F or above 90°F.
- Hot or cold weather will affect dry times.
- Epoxy must be cured for a minimum of 24 hours before coming in contact with water.
- Skid-resistant additives are available, such as CA-30 or CA-31.
- For interior use only unless protected by a UV-resistant coating.
- Solvents may be required in cooler weather to lower viscosity and increase coverage of 100% solids.
- Please check with local laws governing the use of solvents.
- Do not allow Westcoat products to freeze.
Properties
- Color
- Physical Properties
Value Units Test Method / Conditions Gloss (60Degrees) 68.0 - - Solids By Volume (Mix) 43.0 % - Solids By Weight (Mix) 49.0 % - Viscosity (Mix) 223.0 cPs - Viscosity (Mix) 53.0 KU - Weight Per Gallon (Mix) 9.0 - - - Typical Properties
Value Units Test Method / Conditions Adhesion on Concrete 4.0 - ASTM D3359 Adhesion on Steel 5.0 - ASTM D3359 Foot Traffic (Over Concrete, 72°F) 2.0 hours - Foot Traffic (Sealed Surface, 72°F) 5.0 hours - Hardness (4weeks) 79.0 Shore D ASTM D2240 Heat Resistance (Constant) 180.0 °F - Heat Resistance (Intermittent) 220.0 °F - Impact Resistance (Direct) 50.0 in-lbs - Impact Resistance (Reverse) 4.0 in-lbs - Mandrel Bend (In 1/4) 180.0 ° - Mix Ratio by Volume 2:1 - - Pencil Hardness 2H - - Reducer/Clean Up Warm Soapy Water - - Tack Free (Over Concrete, 72°F) 1.0 hours - VOC Content max. 25 gm/l - Wheel Traffic 72.0 hours -
Regulatory & Compliance
- Certifications & Compliance
- Certifications
VOC Emission Test Certificate - Certificate No: 190516-05
Technical Details & Test Data
- Chemical Resistance
Clear & Pigmented Muriatic Acid (31.5% HCL) 2 Sulfuric Acid (50% H2SO4) 4 Sulfuric Acid (93% H2SO4) 1 Nitric Acid (10% HNO3) 2 Sodium Hydroxide (50% NaOH) 5 Bleach (sodium hypochlorite) 5 Vinegar (3-5% acetic acid) 2 Transmission Fluid 5 Gasoline 5 Brake Fluid 5 409 Surface Cleaner 5 Pine Sol Solution 5 Blood & Body Fluids 5 Iodine Solution 5 Mustard 5/5s Ketchup 5/5 Red Wine 5/5 Acetone 4 Methyl Ethyl Ketone (MEK) 5 Xylene 5 Ethanol 5 Methanol 5
Key:
- 5 = Best (no effect)
- 4 = Softens (recovers)
- 3 = Softens (no recovery)
- 2 = Blistered (no recovery)
- 1 = Worst Destroyed
- s = With Stain
- * Contact time > 5hrs = 1
Safety & Health
- Health Precautions
- Inhalation of vapor or mist can cause headache, nausea irritation of nose, throat, and lungs.
- Avoid breathing vapors, it is strongly recommended that respirators are worn.
- Prolonged or repeated skin contact can cause slight skin irritation.
- All epoxies have the potential of causing skin irritations or allergic reactions.
- Be careful not to get on skin, clothes or in eyes.
- Gloves are strongly recommended.
- If splashed in the eye, flush with warm water and contact a physician if blurring persists.
- Slip Precaution
- Westcoat Specialty Coatings Systems highly recommends the use of a slip-resistant additive to all coatings/systems that may be exposed to wet, oily, greasy or slippery conditions.
- It is the end user’s responsibility to provide a flooring system that meets current safety standards.
- Westcoat and its distributors will not be responsible for injury incurred during a slip and fall incident.
- For the current coefficient of friction requirements, please consult your local building codes.
Packaging & Availability
- Packaging
1.5 gal & 15 gal kits available.
Storage & Handling
- Pot Life
- 60 - 90 minutes (Gel Time, 150gm, 72°F)
- Shelf Life