Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Cleaning Ingredients Functions
- Industrial Additives Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- HII Features
- Features
Preservative Free
- Functional Properties
- Instant wetting
- High Cloud Point
- High Density
- Low Pour Point
- High Flash Point
- Benefits
Preservative Free.
- Biodegradability
Based on the components, STEPOSOL CITRI-MET is expected to be readily biodegradable.
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Industrial Additives End Use
- Applications
STEPOSOL CITRI-MET is a moderately alkaline, concentrated cleaning blend of solvents and surfactants that can be used at several different dilutions, depending on the soil and surface being cleaned. From as-is to 1:4 dilutions with water, it functions as a graffiti remover, latex paint stripper, and heavy oil/tar removal. At dilutions in the range of 1:14, it can function as a marker and ink remover, degreaser, bug/tar remover, blood stain remover, carpet cleaner, and laundry pre-wash spot remover. At higher levels of dilution, it can be used as an all-purpose or glass cleaner.
- End-Use Applications
- Graffiti Removal
- Bug and Tar Remover
- Degreaser
- Kitchen Cleaner
- Marker/Ink Remover
- Wall and Tile Cleaner
- All-Purpose Cleaner
- Oilfield Rig Wash
- Carpet Cleaner
- Laundry Pre-Treat
- Industrial Laundry
- Performance
Coatings Removal Test (ASTM D6189-97): STEPOSOL CITRI-MET cleans coatings effectively. Greater than 90% removal of spray paint graffiti, latex paint, tar, and dried-on crude oil is observed within 10 minutes when used at 1:4 dilution. Greater than 90% simulated road tar is removed within 2 minutes when used at 1:14 dilution.
Properties
- Physical Form
- Appearance
- Clear to slightly hazy liquid (at 25°C)
- Typical Properties
Value Units Test Method / Conditions Cloud Point min. 70 °C - Solids Content 51 % - Water Content 36 % - pH 10.8 - - Color (Transmittance at 420 nm) min. 80 % - Viscosity (at 25°C) 25 cPs - Pour Point -16 °C - Flash Point 57.5 °C PMCC Flash Point Tester Density (at 25°C) 1.08 g/ml - Critical Micelle Concentration (CMC) 40.4 mg/L - Surface Tension (at CMC) 31.8 dynes/cm - Draves Wetting (at 25 °C, 1:100 dilution) 0 sec - Draves Wetting (at 25 °C, 1:500 dilution) 8 sec - Draves Wetting (at 25 °C, 1:1000 dilution) 67 sec - Regulated Volatile Organic Chemicals 7.5 % U.S. EPA
Regulatory & Compliance
- Chemical Inventories
- Clearances
The international inventories (country clearances) of STEPOSOL CITRI-MET can be found in Section 15 of the Safety Data Sheet (SDS). It is the responsibility of the formulator to review the chemical control regulations for each country where the end product is intended to be sold or used.
Packaging & Availability
- Packaging Type
- Standard Packaging
STEPOSOL CITRI-MET is available in bulk, 55-gallon drums, and tote quantities.
Storage & Handling
- Storage & Handling
Normal safety precautions (i.e., gloves and safety goggles) should be employed when handling STEPOSOL CITRI-MET. Contact with eyes, nose or prolonged contact with skin should be avoided. Wash thoroughly after handling STEPOSOL CITRI-MET. Stepan’s recommended retest date for this product is 36 months (3 years) from the date of manufacture. After 36 months, we recommend that the customer re-analyze to ensure product is within specification.
Recommended Storage Conditions
It is recommended that STEPOSOL CITRI-MET be stored in a dry place in sealed containers at 50-122 °F (10-50 °C). Avoid overheating or freezing.
Freeze Statement
If material is frozen or appears to have separated, warm to room temperature with agitation. Ensure the material is homogenous (single phase of clear to slightly hazy liquid) before use and /or dilution to final product concentration.
- Bulk Storage Information - STEPOSOL CITRI-MET can be stored in tanks made of 316 stainless steel or HDPE.
- Recommended Storage Temperature: 50-122 °F (21-50 °C).
- Maximum Storage Temperature: 122 °F (50 °C)
- Workplace Exposure
Occupational exposure can occur primarily through skin contact or via inhalation of vapors and mists. Engineering controls, personal protective equipment, and other workplace practices should be used to control these exposures.