Identification & Functionality
- Chemical Family
- Chemical Name
- INCI Name
- Cleaning Ingredients Functions
- Cosmetic Ingredients Functions
- Molecular formula
- CH₃(CH₂)ₙCH₂(OCH₂CH₂)₃OSO₃Na (n = 8 - 14, alt. n = 10 - 13)
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Home Care Applications
- I&I Cleaning Applications
- Personal Hygiene Applications
Properties
- Physical Form
- Appearance
- Clear liquid
- Typical Properties
Value Units Test Method / Conditions Active Content 60.0 % - Boiling Point 88.0 °C - Density (at 25°C) 1.03 g/ml - Flash Point 26.0 °C Pensky–Martens closed-cup Freeze Point -4.0 °C - Ethylene Oxide Content 3.0 moles - pH (10% aqueous) 8.3 - - Pour Point -1.0 °C - Specific Gravity (at 25°C) 1.03 - - Viscosity (at 25°C) 55.0 cps - Regulated Volatile Organic Chemicals Content (Ethanol) 14.0 U.S. EPA % - 1,4-Dioxane Content (as is, when produced) max. 3 - - Level of Ethoxylation (average) 3.0 moles - Color (at 430 nm, 28% active in 50:50 Ethanol:Water at 25°C) max. 50 %T - Sodium Chloride Content max. 0.2 % - Sodium Sulfate Content max. 0.5 % -
Regulatory & Compliance
- Certifications & Compliance
Storage & Handling
- Storage and Handling
Normal safety precautions (i.e., gloves and safety goggles) should be employed when handing STEOL CS-460 ULTRA. Contact with eyes, nose or prolonged contact with skin should be avoided. Wash thoroughly after handling STEOL CS-460 ULTRA.
- Standard Packaging: STEOL CS-460 ULTRA is available in bulk, tote and drum quantities.
- Non-Bulk Storage Recommendations: It is recommended that STEOL CS-460 ULTRA be stored in sealed containers kept in well-ventilated area away from sparks, fire, and open flame. Avoid overheating and freezing. Equipment should be grounded when transferring or using material.
- Bulk Storage Recommendations: STEOL CS-460 ULTRA should be stored in vessels of 316 stainless steel or fiberglass with an Atlac 382 corrosion liner, atmospheric storage with a flame arrestor, and electrically grounded fittings are recommended. Pumps, pipes and transfer lines should be 316 stainless steel.
1,4-Dioxane may increase over time. The rate of 1,4-dioxane increase is affected by time, temperature, and pH. The rate of 1,4-dioxane increase is minimized when product is stored at or below 25°C (77°F). Product stored at temperatures above 25°C (77°F) can accelerate 1,4-dioxane formation. Stepan encourages customers to test the 1,4-dioxane level of their final formulations in accordance with their established testing protocols.