Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Key Characteristics
Moisture-curable TPO Compound
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
Properties
- Physical Form
- Mechanical Properties
Value Units Test Method / Conditions Elongation at Break 400 % ASTM D638 Elongation Under Load (Hot Elongation Test: 15 min / 150°C, 0.2 N/mm² Load) 35 % SACO AEI DWI-QA-4007 based on ICEA T-28-562 Tensile Strength at Break 2500 psi ASTM D638 - Physical Properties
Value Units Test Method / Conditions Bulk Density 0.53 g/cc ASTM D1895 Degree of Cross-linking 86 % ASTM D2765 Melt Flow Rate (at 190°C / 2.16kg) 0.5 g/10min ASTM D1238 Shore A 80 Shore A ASTM D2240 Hardness 80 Shore A ASTM D2240 Shore D 40 Shore D ASTM D2240 Hardness 40 Shore D ASTM D2240 Specific Gravity (at 23°C) 0.9 g/cm³ ASTM D792
Packaging & Availability
- Packaging Information
The physical form of A-3021 is free flowing pellets, available in 1300-lb gaylords or 300-lb fiber drums.
Storage & Handling
- Storage and Handling
PEXIDAN® A-3021 is a moisture-reactive compound and exposure to ambient moisture prior to use must be avoided. For optimum performance the product is packaged dry in a heat-sealed aluminized liner and should be kept in its sealed liner until use. Un-used portions in opened packaging should be used within days. Proper evacuation and resealing may allow A-3021 to be re-stored for several weeks after initial opening but this practice should be avoided, and SĀCO AEI makes no warranties about its fitness for purpose if this practice is followed.
A-3021 should never be dried, and A-3021 removed from the packaging should not be returned to the packaging. In order to prevent prescorching this grafted compound and the catalyst masterbatch must be stored separately and mixed only when used. Un-used mixtures must be discarded. It is recommended that un-opened A-3021 be used within 6 months from the date of manufacture printed on the packaging