Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Additives Included
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Flame Rating
- Mechanical Properties
Value Units Test Method / Conditions Taber Abrasion (CS-17, 1 kg) ¹¹ 65 mg/1000cy SABIC method Tensile Stress (Break, Type I, 5 mm/min) ¹¹ 106 MPa ASTM D638 Tensile Stress (Break, Type I, 50 mm/min) ¹¹ 120 MPa ASTM D638 Tensile Strain (Break, Type I, 5 mm/min) ¹¹ 5 % ASTM D638 Tensile Strain (Break, Type I, 50 mm/min) ¹¹ 3 % ASTM D638 Tensile Stress (Break, 5 mm/min) ¹¹ 80 MPa ISO 527 Flexural Stress (Yield, 2.6 mm/min, 100 mm span) ¹¹ 151 MPa ASTM D790 Tensile Modulus (at 5 mm/min) ¹¹ 7100 MPa ASTM D638 Tensile Strain (Break, 5 mm/min) ¹¹ 2 % ISO 527 Flexural Modulus (at 2.6 mm/min, 100 mm span) ¹¹ 5720 MPa ASTM D790 Flexural Stress (Yield, 1.3 mm/min, 50 mm span) ¹¹ 140 MPa ASTM D790 Tensile Modulus (at 1 mm/min) ¹¹ 6400 MPa ISO 527 Tensile Modulus (at 1 mm/min) ¹¹ 5500 MPa ISO 527 Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹ 5500 MPa ASTM D790 Flexural Stress (Break, 2 mm/min) ¹¹ 125 MPa ISO 178 Hardness (Rockwell L) ¹¹ 106 - ASTM D785 Flexural Modulus (at 2 mm/min) ¹¹ 5600 MPa ISO 178 Flexural Modulus (at 2 mm/min) ¹¹ 4500 MPa ISO 178 Tensile Stress (Break, 50 mm/min) ¹¹ 100 MPa ISO 527 Ball Indentation Hardness (H358/30) ¹¹ 125 MPa ISO 2039-1 Tensile Strain (Break, 50 mm/min) ¹¹ 2.5 % ISO 527 Flexural Stress (Yield, at 2 mm/min) ¹¹ 150 MPa ISO 178 - Physical Properties
Value Units Test Method / Conditions Specific Gravity ¹¹ 1.23 - ASTM D792 Specific Gravity ¹¹ 1.25 - ASTM D792 Water Absorption (at 23°C, 24hrs) ¹¹ 0.11 % ISO 62-1 Water Absorption (at 23°C, 24hrs) ¹¹ 0.06 % ASTM D570 Mold Shrinkage (flow, 3.2 mm) ᵍ ¹¹ 0.2 - 0.5 % SABIC method Mold Shrinkage (on Tensile Bar, flow) ᵍ ¹¹ 0.2 - 0.4 % SABIC method Density ¹¹ 1.25 g/cm³ ISO 1183 Melt Flow Rate (at 280°C, 5.0 kgf) ¹¹ 3.5 g/10 min ASTM D1238 Water Absorption (at 23°C, saturated) ¹¹ 0.22 % ISO 62-1 Moisture Absorption (at 23°C, 50% RH, Equilibrium) ¹¹ 0.04 % ISO 62-4 Moisture Absorption (at 23°C, 50% RH) ¹¹ 0.07 % ISO 62 Melt Volume Rate (at 280°C, 10.0 kg) ¹¹ 12 cm³/10 min ISO 1133 Melt Volume Rate (at 280°C, 5.0 kg) ¹¹ 3 cm³/10 min ISO 1133 - Thermal Properties
Value Units Test Method / Conditions Heat Deflection Temperature (at 0.45 MPa, 6.4 mm, Unannealed) ¹¹ 137 °C ASTM D648 Heat Deflection Temperature (at 1.82 MPa, 6.4 mm, Unannealed) ¹¹ 132 °C ASTM D648 Coefficient of Thermal Expansion (at -40°C to 95°C, flow) ¹¹ 0.000036 1/°C ASTM E831 Relative Temperature Index (Electrical) ᵖ ¹¹ 110 °C UL 746B Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ 0.00003 1/°C ISO 11359-2 Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ 0.00005 1/°C ASTM E831 Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ 0.00005 1/°C ISO 11359-2 Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ 0.000025 1/°C ASTM E831 Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ 105 °C UL 746B Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹ 0.000075 1/°C ISO 11359-2 Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹ 0.000068 1/°C ASTM E831 Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹ 0.000068 1/°C ISO 11359-2 Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹ 7.50E-05 1/°C ASTM E831 Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ 110 °C UL 746B Thermal Conductivity ¹¹ 0.28 W/m-°C ISO 8302 Coefficient of Thermal Expansion (at 23°C to 80°C, flow) ¹¹ 0.00003 1/°C ISO 11359-2 Coefficient of Thermal Expansion (at 23°C to 80°C, xflow) ¹¹ 0.00007 1/°C ISO 11359-2 Ball Pressure Test (at 123°C to 127°C) ¹¹ Pass - IEC 60695-10-2 Ball Pressure Test (approximate maximum) ¹¹ 135 °C IEC 60695-10-2 Vicat Softening Temperature (Rate B/50) ¹¹ 142 °C ISO 306 Vicat Softening Temperature (Rate B/50) ¹¹ 142 °C ASTM D1525 Vicat Softening Temperature (Rate B/50) ¹¹ 140 °C ISO 306 Heat Deflection Temperature (at 0.45 MPa, 3.2 mm, Unannealed) ¹¹ 142 °C ASTM D648 Vicat Softening Temperature (Rate A/50) ¹¹ 150 °C ISO 306 Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹ 134 °C ASTM D648 Vicat Softening Temperature (Rate B/120) ¹¹ 145 °C ISO 306 Vicat Softening Temperature (Rate B/120) ¹¹ 144 °C ISO 306 Heat Deflection Temperature/Be (at 0.45MPa, Edgew 120*10*4, sp=100mm) ¹¹ 135 °C ISO 75/Be Heat Deflection Temperature/Ae (at 1.8 Mpa, Edgew 120*10*4, sp=100mm) ¹¹ 130 °C ISO 75/Ae Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ 133 °C ISO 75/Af - Electrical Properties
Value Units Test Method / Conditions Dielectric Strength (in oil, at 3.2mm) ¹¹ 16 kV/mm IEC 60243-1 Dielectric Strength (in oil, at 3.2mm) ¹¹ 23.6 kV/mm ASTM D149 Relative Permittivity (50/60 Hz) ¹¹ 3 - IEC 60250 Relative Permittivity (50/60 Hz) ¹¹ 2.98 - ASTM D150 Dissipation Factor (at 50/60 Hz) ¹¹ 0.0016 - ASTM D150 Dissipation Factor (at 50/60 Hz) ¹¹ 0.004 - IEC 60250 High Voltage Arc Track Rate (PLC) ¹¹ 4 PLC Code UL 746A High Voltage Arc Track Rate (PLC) ¹¹ 3 PLC Code UL 746A Comparative Tracking Index (UL, PLC) ¹¹ 3 PLC Code UL 746A Comparative Tracking Index (UL, PLC) ¹¹ 2 PLC Code UL 746A Comparative Tracking Index (UL, PLC) ¹¹ 1 PLC Code UL 746A High Ampere Arc Ignition (PLC 2) ¹¹ min. 1.5 mm UL 746A Hot Wire Ignition (PLC 0) ¹¹ min. 1.5 mm UL 746A Hot Wire Ignition (PLC 0) ¹¹ min. 0.71 mm UL 746A Arc Resistance (Tungsten, PLC) ¹¹ 6 PLC Code ASTM D495 Volume Resistivity ¹¹ 1.00E+15 Ω.cm IEC 60093 Volume Resistivity ¹¹ 2.04E+16 Ω.cm ASTM D257 Volume Resistivity ¹¹ 2.04E+16 Ω.cm IEC 60093 Surface Resistivity (ROA) ¹¹ min. 1.E+15 Ω IEC 60093 Surface Resistivity (ROA) ¹¹ 1.34E+17 Ω IEC 60093 Surface Resistivity ¹¹ 1.34E+17 Ω ASTM D257 Dielectric Strength (in oil, at 0.8mm) ¹¹ 30 kV/mm IEC 60243-1 Dielectric Strength (in oil, at 1.6mm) ¹¹ 25 kV/mm IEC 60243-1 Dielectric Strength (in oil, at 1.6mm) ¹¹ 26.2 kV/mm ASTM D149 Relative Permittivity (1 MHz) ¹¹ 2.9 - IEC 60250 Relative Permittivity (1 MHz) ¹¹ 2.93 - ASTM D150 Dissipation Factor (at at 1 MHz) ¹¹ 0.002 - IEC 60250 Dissipation Factor (at at 1 MHz) ¹¹ 0.0034 - ASTM D150 Dissipation Factor (at at 1 MHz) ¹¹ 0.0034 - IEC 60250 Dielectric Strength (in oil, at 1.5mm) ¹¹ 26.2 kV/mm IEC 60243-1 Comparative Tracking Index ʳ ¹¹ 225 V IEC 60112 High Ampere Arc Ignition (PLC 3) ¹¹ min. 6 mm UL 746A High Ampere Arc Ignition (PLC 4) ¹¹ min. 1.5 mm UL 746A High Ampere Arc Ignition (PLC 4) ¹¹ min. 0.4 mm UL 746A Hot Wire Ignition (PLC 2) ¹¹ min. 0.4 mm UL 746A - Impact Properties
Value Units Test Method / Conditions Izod Impact (Notched, at 23°C) ¹¹ 100 J/m ASTM D256 Izod Impact (Notched, at 23°C) ¹¹ 106 J/m ASTM D256 Izod Impact (Notched, at -40°C) ¹¹ 96 J/m ASTM D256 Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ 25 kJ/m² ISO 180/1U Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ 28 kJ/m² ISO 180/1U Izod Impact (Unnotched, 80*10*4, at -30°C) ¹¹ 25 kJ/m² ISO 180/1U Izod Impact (Unnotched, 80*10*4, at -30°C) ¹¹ 27 kJ/m² ISO 180/1U Charpy Impact (at 23°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹ 30 kJ/m² ISO 179/1eU Charpy Impact (at -30°C, Unnotch Edgew 80*10*4 sp=62mm) ¹¹ 30 kJ/m² ISO 179/1eU Izod Impact (Unnotched, at 23°C) ¹¹ 520 J/m ASTM D4812 Izod Impact (Notched, at -30°C) ¹¹ 90 J/m ASTM D256 Instrumented Dart Impact Total Energy (at 23°C) ¹¹ 18 J ASTM D3763 Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ 9 kJ/m² ISO 180/1A Izod Impact (Notched, 80*10*4, at -30°C) ¹¹ 8 kJ/m² ISO 180/1A Charpy Impact (Notched, at 23°C) ¹¹ 7 kJ/m² ISO 179/2C - Injection Molding
Value Units Test Method / Conditions Drying Temperature ⁷ 100 - 120 °C - Drying Temperature ⁷ 110 - 120 °C - Drying Time ⁷ 3 - 4 Hrs - Drying Time ⁷ 2 - 3 Hrs - Drying Time (Cumulative) ⁷ 8 Hrs - Melt Temperature ⁷ 280 - 300 °C - Melt Temperature ⁷ 300 - 325 °C - Maximum Moisture Content ⁷ 0.02 % - Nozzle Temperature ⁷ 260 - 280 °C - Nozzle Temperature ⁷ 300 - 325 °C - Front - Zone 3 Temperature ⁷ 280 - 300 °C - Front - Zone 3 Temperature ⁷ 290 - 325 °C - Middle - Zone 2 Temperature ⁷ 260 - 280 °C - Middle - Zone 2 Temperature ⁷ 275 - 320 °C - Rear - Zone 1 Temperature ⁷ 240 - 260 °C - Rear - Zone 1 Temperature ⁷ 265 - 315 °C - Hopper Temperature ⁷ 60 - 80 °C - Mold Temperature ⁷ 80 - 110 °C - Mold Temperature ⁷ 80 - 120 °C - Back Pressure ⁷ 0.3 - 0.7 MPa - Screw Speed ⁷ 20 - 100 rpm - Shot to Cylinder Size ⁷ 30 - 70 % - - Flame Characteristics
Value Units Test Method / Conditions UL Recognized (94-5VA Flame Class Rating) ʳ min. 2 mm UL 94 UL Recognized (94-5VA Flame Class Rating) ʳ min. 2.5 mm UL 94 UL Recognized (94V-0 Flame Class Rating) ʳ min. 6 mm UL 94 UL Recognized (94V-1 Flame Class Rating) ʳ min. 1.5 mm UL 94 UL Recognized (94V-1 Flame Class Rating) ʳ min. 0.4 mm UL 94 Glow Wire Flammability Index (at 1 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Flammability Index (at 1.5 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Flammability Index (at 2 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Ignitability Temperature (at 1.0 mm) ʳ 800 °C IEC 60695-2-13 Glow Wire Ignitability Temperature (at 1.0 mm) ʳ 775 °C IEC 60695-2-13 Glow Wire Ignitability Temperature (at 1.5 mm) ʳ 750 °C IEC 60695-2-13 UV-light (Water exposure/immersion) ʳ F1 - UL 746C UV-light (Water exposure/immersion) ʳ F2 - UL 746C Oxygen Index (LOI) ʳ 30 % ISO 4589 Oxygen Index (LOI) ʳ 30.9 % ASTM D2863 Glow Wire Ignitability Temperature (at 2.0 mm) ʳ 800 °C IEC 60695-2-13 - Note
- ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
- ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
- ʳ UL Ratings shown on the technical datasheet might not cover the full range of thicknesses, colors and regions. For details, please see the UL Yellow Card.
- ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability