- Flame Rating
- Mechanical Properties
Value Units Test Method / Conditions Tensile Stress (Yield, Type I, 50 mm/min) ¹¹ 60 MPa ASTM D638 Tensile Stress (Break, Type I, 50 mm/min) ¹¹ 47 MPa ASTM D638 Tensile Strain (Yield, Type I, 50 mm/min) ¹¹ 3.6 % ASTM D638 Tensile Strain (Break, Type I, 50 mm/min) ¹¹ 9 % ASTM D638 Tensile Modulus (at 50 mm/min) ¹¹ 2580 MPa ASTM D638 Flexural Stress (Yield, 1.3 mm/min, 50 mm span) ¹¹ 98 MPa ASTM D790 Flexural Stress (Yield, 2.6 mm/min, 100 mm span) ¹¹ 91 MPa ASTM D790 Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹ 2500 MPa ASTM D790 Flexural Modulus (at 2.6 mm/min, 100 mm span) ¹¹ 2300 MPa ASTM D790 Hardness (Rockwell R) ¹¹ 120 - ASTM D785 Taber Abrasion (CS-17, 1 kg) ¹¹ 76 mg/1000cy ASTM D1044 Tensile Stress (Yield, 50 mm/min) ¹¹ 58 MPa ISO 527 Tensile Stress (Break, 50 mm/min) ¹¹ 50 MPa ISO 527 Tensile Strain (Yield, 50 mm/min) ¹¹ 3.2 % ISO 527 Tensile Strain (Break, 50 mm/min) ¹¹ 9.2 % ISO 527 Tensile Modulus (at 1 mm/min) ¹¹ 2600 MPa ISO 527 Flexural Stress (Yield, at 2 mm/min) ¹¹ 8.70E+01 MPa ISO 178 Flexural Modulus (at 2 mm/min) ¹¹ 2350 MPa ISO 178 - Physical Properties
Value Units Test Method / Conditions Specific Gravity ¹¹ 1.13 - ASTM D792 Water Absorption (at 23°C, 24hrs) ¹¹ 0.08 % ASTM D570 Mold Shrinkage (flow, 3.2 mm) ᵍ ¹¹ 0.5 - 0.7 % SABIC method Melt Flow Rate (at 250°C, 10.0 kgf) ¹¹ 19.3 g/10 min ASTM D1238 Melt Volume Rate (at 280°C, 5.0 kg) ¹¹ 23 cm³/10 min ISO 1133 Melt Flow Rate (at 280°C, 5.0 kgf) ¹¹ 20 g/10 min ASTM D1238 - Thermal Properties
Value Units Test Method / Conditions Vicat Softening Temperature (Rate B/50) ¹¹ 104 °C ASTM D1525 Heat Deflection Temperature (at 0.45 MPa, 3.2 mm, Unannealed) ¹¹ 95 °C ASTM D648 Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹ 78 °C ASTM D648 Heat Deflection Temperature (at 1.82 MPa, 6.4 mm, Unannealed) ¹¹ 86 °C ASTM D648 Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ 0.000077 1/°C ASTM E831 Coefficient of Thermal Expansion (at -40°C to 40°C, xflow) ¹¹ 0.000081 1/°C ASTM E831 Thermal Conductivity ¹¹ 0.24 W/m-°C ASTM C177 Vicat Softening Temperature (Rate B/120) ¹¹ 107 °C ISO 306 Heat Deflection Temperature/Bf (at 0.45 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ 95 °C ISO 75/Bf Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ 82 °C ISO 75/Af Relative Temperature Index (Electrical) ᵖ ¹¹ 95 °C UL 746B Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ 80 °C UL 746B Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ 95 °C UL 746B - Electrical Properties
Value Units Test Method / Conditions Volume Resistivity ¹¹ 1.80E+16 Ω.cm ASTM D257 Dielectric Strength (in oil, at 3.2mm) ¹¹ 19.2 kV/mm ASTM D149 Relative Permittivity (100 Hz) ¹¹ 2.74 - ASTM D150 Relative Permittivity (100 kHz) ¹¹ 2.6 - ASTM D150 Dissipation Factor (at 100 Hz) ¹¹ 0.013 - ASTM D150 Dissipation Factor (at 100 kHz) ¹¹ 0.0055 - ASTM D150 High Voltage Arc Track Rate (PLC) ¹¹ 4 PLC Code UL 746A Comparative Tracking Index (UL, PLC) ¹¹ 1 PLC Code UL 746A High Ampere Arc Ignition (PLC 0) ¹¹ min. 6 mm UL 746A High Ampere Arc Ignition (PLC 2) ¹¹ min. 1.5 mm UL 746A Hot Wire Ignition (PLC 1) ¹¹ min. 6 mm UL 746A Hot Wire Ignition (PLC 2) ¹¹ min. 1.5 mm UL 746A Arc Resistance (Tungsten, PLC) ¹¹ 7 PLC Code ASTM D495 - Impact Properties
Value Units Test Method / Conditions Izod Impact (Unnotched, at 23°C) ¹¹ 720 J/m ASTM D4812 Izod Impact (Notched, at 23°C) ¹¹ 293 J/m ASTM D256 Izod Impact (Unnotched, at -30°C) ¹¹ 100 J/m ASTM D4812 Izod Impact (Notched, at -30°C) ¹¹ 100 J/m ASTM D256 Instrumented Dart Impact Energy (Peak, at 23°C) ¹¹ 50 J ASTM D3763 Instrumented Dart Impact Total Energy (at 23°C) ¹¹ 50 J ASTM D3763 Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ 20 kJ/m² ISO 180/1A Charpy Impact (Notched, at 23°C) ¹¹ 20 kJ/m² ISO 179/2C - Injection Molding
Value Units Test Method / Conditions Drying Temperature ⁷ 75 - 80 °C - Drying Time ⁷ 3 - 4 Hrs - Drying Time (Cumulative) ⁷ 8 Hrs - Maximum Moisture Content ⁷ 0.02 % - Melt Temperature ⁷ 250 - 275 °C - Nozzle Temperature ⁷ 250 - 275 °C - Front - Zone 3 Temperature ⁷ 240 - 275 °C - Middle - Zone 2 Temperature ⁷ 225 - 270 °C - Rear - Zone 1 Temperature ⁷ 215 - 265 °C - Mold Temperature ⁷ 55 - 75 °C - Back Pressure ⁷ 0.3 - 0.7 MPa - Screw Speed ⁷ 20 - 100 rpm - Shot to Cylinder Size ⁷ 30 - 70 % - Vent Depth ⁷ 0.038 - 0.051 mm - - Flame Characteristics
Value Units Test Method / Conditions UL Recognized (94-5VA Flame Class Rating) ʳ min. 3 mm UL 94 UL Recognized (94HB Flame Class Rating) ʳ min. 1 mm UL 94 UL Recognized (94V-0 Flame Class Rating) ʳ min. 1.5 mm UL 94 Glow Wire Flammability Index (at 1 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Flammability Index (at 2 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Flammability Index (at 3 mm) ʳ 960 °C IEC 60695-2-12 Glow Wire Ignitability Temperature (at 1.0 mm) ʳ 800 °C IEC 60695-2-13 Glow Wire Ignitability Temperature (at 2.0 mm) ʳ 775 °C IEC 60695-2-13 Glow Wire Ignitability Temperature (at 3.0 mm) ʳ 775 °C IEC 60695-2-13 UV-light (Water exposure/immersion) ʳ F1 - UL 746C Oxygen Index (LOI) ʳ 39 % ASTM D2863 - Note
- ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
- ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
- ʳ UL Ratings shown on the technical datasheet might not cover the full range of thicknesses, colors and regions. For details, please see the UL Yellow Card.
- ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.