NuSil™ MED-5440

NuSil™ MED-5440 is a fluorosilicone liquid silicone rubber.

Brand: NuSil (565 products)

Polymer Name: Fluorosilicone

Processing Methods: Injection Molding

End Uses: Drug Delivery Pens, Gaskets, Medical/Healthcare Applications, Valve Parts, Valves

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Product Highlights
  • Two-part, translucent, fluorosilicone elastomer used with liquid injection molding equipment
  • 100 mol % fluorosilicone
  • Cures with heat via addition-cure chemistry
  • 1:1 Mix Ratio (Part A: Part B)

Applications & Uses

Markets
Applications
Cure Method
Plastics & Elastomers End Uses
Plastics & Elastomers Processing Methods
Applications
  • For the injection molding of parts requiring a material with a medium durometer including: molded rubber stoppers, gaskets, seals, valves, o-rings
  • and other precision parts
  • Suitable for over-molding applications
Instructions for Use

Mixing

Combine Part A and Part B in a 1:1 mix ratio prior to use. Airless mixing, metering or dispensing equipment is recommended for production operations. If mixing by hand, take care to minimize air entrapment.

Vacuum Deaeration

Remove air entrapped during mixing by common vacuum deaeration procedure, observing all applicable safety precautions. Slowly apply full vacuum to a suitable container of at least four times the volume of material being de-aired. Hold vacuum until bulk deaeration is complete.

Substrate Considerations

Cures in contact with most materials common to biomedical assemblies, exceptions include: sulfur-cured organic rubbers, latex, chlorinated rubbers, some RTV silicones and unreacted residues of some curing agents.

Vulcanization

Curing of the blended elastomer is accelerated by heat. The pre-measured catalyst provides a fixed cure rate. Do not attempt to change molding times by mixing the two components in any other than a 1:1 ratio, as this will affect the properties of the elastomer. Only temperature adjustments should be employed to alter the rate of cure.

Properties

Appearance
Translucent
Typical Properties
ValueUnitsTest Method / Conditions
Durometer Type A30.0--
Tensile1,250 (8.62 )psi (MPa)-
Elongat ion380.0%-
Tear60 (10.58 )ppi (kN/m)-
Extrusion Rat e40.0g/minute-
Mix Rat io0.042361111--
Specific Gravity1.38--
Cured Properties
ValueUnitsTest Method / Conditions
Cure at 150 °C30.0minutes-
Cure SystemPlatinum--

Packaging & Availability

Country Availability
Regional Availability
  • Asia Pacific
  • Europe
  • Latin America
  • North America