- Mechanical Properties
Value Units Test Method / Conditions Flexural Modulus (Dry) 2800.0 MPa ISO 178 Flexural Stress (Dry, 3.5% Strain) 95.0 MPa ISO 178 Tensile Modulus (Dry) 3200.0 MPa ISO 527 Tensile Stress at Yield (Dry) 90.0 MPa ISO 527 Tensile Elongation at Yield (Dry) 3.8 % ISO 527 Tensile Elongation at Break (Dry) 15.0 % ISO 527 Impact Strength (Dry, Charpy, at 23°C) no break kJ/m² ISO 179/1eU Notched Impact Strength (Dry, Charpy, at 23°C) 4.0 kJ/m² ISO 179/1eA - Physical Properties
Value Units Test Method / Conditions Density (Dry) 1130.0 kg/m³ ISO 1183 - Thermal Properties
Value Units Test Method / Conditions HDT / A (Dry, 1.8 MPa) 65.0 °C ISO 75-1/-2 DSC (Melt Point, Dry) 220.0 °C ISO 11357 - Typical Properties
Value Units Test Method / Conditions Moisture Content max. 0.15 % - - Flammability
Value Units Test Method / Conditions Flammability (Dry, 1.5 mm) V - 2 class UL 94 UL Recognition (Dry) yes - - - Processing Information (Injection Molding)
Value Units Test Method / Conditions Melt Temperature 250 - 270 °C - Mould Temperature 40 - 80 °C - - Rheological Properties
Value Units Test Method / Conditions Shrinkage (Lengthwise, 24h) 1.2 - 1.4 % ISO 294-4 Shrinkage (Lateral, 24h) 1.2 - 1.4 % ISO 294-4
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- 80 °C in a dry air (dessiccant) dryer for 2-12 h
- Dependant on moisture content
Storage & Handling
- Storage Conditions
Store in dry, protected from light not above 30°C.