Properties
- Mechanical Properties
Value Units Test Method / Conditions Flexural Modulus 2400.0 MPa ISO 178 Flexural Stress (3.5% Strain) 76.0 MPa ISO 178 Tensile Modulus 2300.0 MPa ISO 527 Tensile Stress at Yield 63.0 MPa ISO 527 Tensile Elongation at Yield 6.0 % ISO 527 Tensile Elongation at Break 110.0 % ISO 527 Impact Strength (Charpy, at 23°C) no break kJ/m² ISO 179/1eU Impact Strength (Charpy, at -40°C) no break kJ/m² ISO 179/1eU Notched Impact Strength (Charpy, at 23°C) 12.0 kJ/m² ISO 179/1eA Notched Impact (Charpy, at -40°C) 12.0 kJ/m² ISO 179/1eA - Physical Properties
Value Units Test Method / Conditions Density 1190.0 kg/m³ ISO 1183 - Thermal Properties
Value Units Test Method / Conditions Vicat B50 142.0 °C ISO 306 HDT / A (1.8 MPa) 130.0 °C ISO 75-1/-2 - Typical Properties
Value Units Test Method / Conditions Moisture Content max. 0.02 % - - Optical Properties
Value Units Test Method / Conditions Total Transmission T(Y) (d=1,0mm, A, 2°) 82.0 % ISO 13468 Total Transmission T(Y) (d=2,0mm, A, 2°) 67.5 % ISO 13468 Total Transmission T(Y) (d=3,0mm, A, 2°) 55.5 % ISO 13468 Total Transmission T(Y) (d=4,0mm, A, 2°) 47.5 % ISO 13468 Haze T(Y) (d=1.0 mm, A, 2°) 93.5 % ISO 13468 Haze T(Y) (d=2.0 mm, A, 2°) 95.0 % ISO 13468 Haze T(Y) (d=3.0 mm, A, 2°) 95.0 % ISO 13468 Haze T(Y) (d=4.0 mm, A, 2°) 95.0 % ISO 13468 Half Power Angle T(Y) (d=1mm, A, 2°) 11.0 Degree - Half Power Angle T(Y) (d=2mm, A, 2°) 29.0 Degree - Half Power Angle T(Y) (d=3mm, A, 2°) 40.0 Degree - Half Power Angle T(Y) (d=4mm, A, 2°) 48.0 Degree - - Flammability
Value Units Test Method / Conditions Flammability (0.75 m) V - 2 class UL 94 Flammability (1.5 mm) HB class UL 94 UL Recognition yes - - Glow Wire (GWFI, 850°C, 2mm) Passed - DIN EN 60695 - Processing Information (Injection Molding)
Value Units Test Method / Conditions Melt Temperature 270 - 310 °C - Mould Temperature 80 - 110 °C - - Rheological Properties
Value Units Test Method / Conditions Melt Index (MVR) 16.0 cm³/10min ISO 1133 MVR Temperature 300.0 °C - MVR Load 1.2 kg - Shrinkage (24h) 0.6 - 0.9 % ISO 294-4
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- 120 °C in a dry air (dessiccant) dryer for 2-4 h
- 120 °C in an air circulating dryer for 4-12 h
Storage & Handling
- Storage Conditions
Store in dry, protected from light.