Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Additives Included
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Mechanical Properties
Value Units Test Method / Conditions Tensile Modulus 2400.0 MPa ISO 527 Tensile Stress at Yield 61.0 MPa ISO 527 Tensile Elongation at Yield 5.6 % ISO 527 Tensile Elongation at Break 45.0 % ISO 527 Impact Strength (Charpy, at 23°C) no break kJ/m² ISO 179/1eU Impact Strength (Charpy, at -40°C) no break kJ/m² ISO 179/1eU Notched Impact Strength (Charpy, at 23°C) 45.0 kJ/m² ISO 179/1eA Notched Impact (Charpy, at -40°C) 12.0 kJ/m² ISO 179/1eA - Physical Properties
Value Units Test Method / Conditions Density 1250.0 kg/m³ ISO 1183 - Thermal Properties
Value Units Test Method / Conditions Vicat B50 141.0 °C ISO 306 - Typical Properties
Value Units Test Method / Conditions Moisture Content max. 0.02 % - - Optical Properties
Value Units Test Method / Conditions Tristimulus Value Y10 of Reflection 91.0 % DIN 5033 Tristimulus Value Y10 of Transm.,d=0.5mm 1.0 % ISO 13468 - Flammability
Value Units Test Method / Conditions Flammability (1.5 mm) V - 2 class UL 94 Glow Wire (GWFI, 850°C, 2mm) Passed - DIN EN 60695 - Processing Information (Injection Molding)
Value Units Test Method / Conditions Melt Temperature 270 - 310 °C - Mould Temperature 80 - 110 °C - - Rheological Properties
Value Units Test Method / Conditions Melt Index (MVR) 15.0 cm³/10min ISO 1133 MVR Temperature 300.0 °C - MVR Load 1.2 kg - Shrinkage (24h) 0.5 - 0.8 % ISO 294-4
Regulatory & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- 120 °C in a dry air (dessiccant) dryer for 2-4 h
- 120 °C in an air circulating dryer for 4-12 h
Storage & Handling
- Storage Conditions
Store in dry, protected from light.