Line Call Out | F712121B3E12K6M5 | - | ASTM F104 |
Compressibility | 7 - 14 | % | ASTM F36J |
Creep relaxation (1/32") | 20 | % | ASTM F38B |
Density | 112 | lb/ft ³ (1.8 g/cc ³) | ASTM F1315 |
Dielectric Strength | 14 | kV/mm | ASTM D149-95a |
Gas Permeability | max. 0.5 | ml/min | DIN 3535/6 |
KLINGER Hot Compression Test Thickness Decrease 572°F (23°C) additional | 17 | % | - |
KLINGER Hot Compression Test Thickness Decrease 73°F (23°C) initial | 14 | % | - |
Leachable Chloride Content | 100 | ppm | FSA Method |
Recovery | min. 50 | % | ASTM F36J |
Sealability | max. 0.25 | ml/hr | ASTM F37A (1/32") |
Thickness Increase ASTM F146 after immersion in ASTM Fuel A, 5h/73°F (23°C) | 0 - 5 | % | - |
Thickness Increase ASTM F146 after immersion in ASTM Fuel B, 5h/73°F (23°C) | 0 - 5 | % | - |
Thickness Increase ASTM F146 after immersion in ASTM Oil IRM 901, 5h/300°F (149°C) | 0 - 5 | % | - |
Thickness Increase ASTM F146 after immersion in ASTM Oil IRM 903, 5h/300°F (149°C) | 0 - 10 | % | - |
Weight increase ASTM F146 after immersion in Fuel B, 5h/73°F (23°C) | max. 10 | % | - |