Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Advantages
- Solvent free
- Outstanding adhesion
- Non-flammable
- Pumps as a single component
- Excellent resistance and durability
- Cures inert, non-toxic permanent seal
Applications & Uses
- Markets
- Applications
- Compatible Substrates & Surfaces
- Application
Shake the catalyst thoroughly. Mix the resin and catalyst at a ratio of 6% to 10% to achieve the desired reaction time. Inject through standard packers utilizing a single component pump, (manual or automatic), until the flow of water slows or the observation of material throughout the crack. Opened containers should be used as soon as possible, protect from heat and humidity. Recap containers using dry nitrogen.
- Typical Applications
- Leaking cracks and joints in dam structures
- Leaking cracks and joints in tunnels wastewater treatment plants
- Underground vaults & manholes
- Elevator pits
- Storm water systems
Properties
- Physical Properties
Value Units Test Method / Conditions Elongation 100.0 % ASTM D-3574 Flash Point (Catalyst) min. 350 °F - Flash Point (Uncured Resin) min. 350 °F ASTM D-3278 Tensile Strength 175.0 psi ASTM D-3574 Viscosity (Catalyst) 7.4 cps ASTM C-1638 Viscosity (Uncured Resin) 250.0 cps ASTM C-1638 - Reaction Time
Quantity of Catalyst Reaction Polymerization 6% 30 seconds 115 seconds 8% 25 seconds 90 seconds 10% 20 seconds 75 seconds
Technical Details & Test Data
- Technical Information
Test results were achieved under laboratory conditions. Statistical variations will occur based upon mixing methods, temperature & humidity, test methodology, site conditions, curing conditions, application methods, and equipment.
Safety & Health
- Safety & Health Precautions
Do not breath dust, fumes, or vapors. Use in adequately ventilated areas or wear appropriate respiratory protection if necessary. Wear protective gloves and clothing and proper eye/face protection. If you get material in your eyes, flush with clean potable water for several minutes. Repeat as necessary and seek proper medical attention. Skin contact, rinse liberally with soap and water. Contaminated clothing should be properly discarded. For More Information, please read the complete Safety Data Sheet.
Packaging & Availability
Storage & Handling
- Storage
Jet Set 10 is sensitive to both temperature and moisture and should be stored between 50°F and 86°F. Shelf-life in unopened containers is 12 months. Opened containers should be consumed as quickly as possible. If storing, cover with nitrogen and reseal to prevent ingress of moisture.