ANCHOR BOND® 25 DEGREE LIQUIDS

Anchor Bond® 25 Degree Liquids is a two component 100% solids epoxy primer designed for applications where temperatures are below freezing or where a rapid patch is necessary.

Brand: ANCHOR BOND (10 products)

Product Type: 2K (2 component) Coating, Primer, Solventless & High Solids Coating

Application Area: Cold Storage Plant, Freezer, Tank Support Base, Walkway

Compatible Substrates & Surfaces: Brick, Concrete, Metal, Wood

Features: Freeze Resistant, Good Surface Gloss

Application Method: Brush, Roller, Spray, Wipe

Chemical Family: Epoxy & Epoxy Derivatives

Technical Data Sheet

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features

Applications & Uses

Markets
Applications
Application Area
Application Method
Compatible Substrates & Surfaces
Recommended For
  • Cold storage areas
  • Freezers
  • Walkways
  • Support bases for tanks and seamless floors
Substrate

ANCHOR BOND® 25° LIQUIDS, with the appropriate primer, suitable for application over concrete, wood, brick, quarry tile and metal. Not recommended for use on asphalt, mastic, gypsum based products or painted surfaces. These must first be removed by mechanical means to expose the substrate prior to priming and overlayment.

Mixing and Application Instructions

Topcoat:
Can be used as a topcoat over Anchor Bond® 2500 Epoxy or Anchor Bond® 25 Degree Mortar

Surface Preparation:

All dirt, oil, dust, foreign contaminants and laitance must be removed to ensure a trouble free bond to the substrate. We recommend that an aggressive shot blast be performed prior to the application of this product. A less adequate method would be acid etching, but the etch should properly profile the substrate. All edges and around columns or beams should be mechanically scarified. All termination points should not be feather edged, but should be saw cut with the termination ending at the sawcut. All large cracks should be V cut and filled with an appropriate crack filler. All expansion joints should be filled with an appropriate joint filler. When overlaying an expansion joint, a single saw cut through the epoxy. Restrict the use of the area to light traffic and non-harsh chemicals until overlay will prevent random fracturing. A test should be made to determine that the concrete is dry (when the surface temperature is above 32°F); this can be done by placing a 4’x4’ plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause disbanding. In any event, the surface must be dry.

Primer: 

No primer is necessary. This material is self priming.

Product Mixing: 

It is important that the liquids be mixed together first. Have the liquids at normal room (70°F) temperature and then take them into the area where the repair is to be made. CAUTION! This material has a very, very short pot life; be prepared to work efficiently and in an organized manner. Mix the liquids in an oversized container quickly and thoroughly until streak free. No induction time is necessary. Mix only an amount of material that can be used in the prescribed pot life period.

Product Application:

The mixed material can be applied by brush, roller or spray. However, the material can also be applied by a suitable serrated squeegee and then back rolled as long as the appropriate thickness recommendations are maintained. Maintain temperatures and relative humidity within the recommended ranges during the application and curing process. If concrete conditions or over aggressive mixing causes air entrapment, then an air release roller tool should be used prior to the coating tacking off to remove the air entrapped in the coating.

Recoat or Topcoating: No recoating or topcoating is necessary. However, if you opt to topcoat the applied mortar, allow it to cure before topcoating. Use the 25° liquids to topcoat or many epoxies and urethanes can be used at elevated temperatures.

Clean up:

Use Xylol

Floor Cleaning:

Caution! Some cleaners may affect the color of the floor installed. Test each cleaner in a small area, utilizing your cleaning technique. If no ill effects are noted, you can continue to clean with the product and process tested.

Restriction: Restrict the use of the area to light traffic and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle.

 

 

 

Properties

Color
Physical Form
Typical Properties
ValueUnitsTest Method / Conditions
Finish CharacteristicsGloss--
Foot Traffic Serviceable (30°F)24.0Hours-
Full Cure (Heavy Traffic, 70°F)2022-02-07Hours-
Light Foot Traffic (70°F)2022-06-08Hours-
Mix Ratio (Part A)56.0oz.-
Mix Ratio (Part B)21.0oz.-
Pot Life (.45 cu ft. mix, 70°F)2022-10-15Minutes-
Recoat or Topcoat (70°F)2022-03-04Hours-
Recommended Thickness / Yield (10 Mils Thickness)160.0sq. ft /gallon-
Solids (Weight)99-100%-

Technical Details & Test Data

Chemical Resistance Data
Reagent Rating
Xylene C
1, 1, 1 Trichloroethane C
Mek A
Methanol A
Ethyl Alcohol C
Skydrol B
10% Sodium Hydroxide D
50% Sodium Hydroxide C
10% Sulfuric Acid C
70% Sulfuric Acid A
10% Hcl (Aq) C
5% Acetic Acid B

Rating key:

A – not recommended
B – 2 hour term splash spill
C – 8 hour term splash spill
D – 72 hour immersion
E – long-term immersion 

Packaging & Availability

Colors Available

Light gray, red, green, dark gray, black, natural. Special colors are available upon request.

Packaging Information

3 gal kits
6 gal kits

Storage & Handling

Shelf Life
2 Years
Storage Conditions

Store product in an area so as to bring the material to normal room temperature before using. Continuous storage should be above 55°F to prevent product crystallization.