Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
Properties
- Flame Rating
- Physical Form
- Flame Rating
- UL 94 V2
- Physical Properties
Value Units Test Method / Conditions Melt Volume Flow Rate - MVR (260°C/2.16kg) 65 cm3/10min ISO 1133 (JIS K7210) Mold Shrinkage - MD (2 mm) 0.5 - 0.7 % Idemitsu Method Mold Shrinkage - TD (2 mm) 0.5 - 0.7 % Idemitsu Method Water Absorption (24h, 50% RH) 0.23 % ISO 62 (JIS K7209) Density 1.2 g/cm3 ISO 1183 - Thermal Properties
Value Units Test Method / Conditions Linear Thermal Expansion Coefficient 6.5 ×10-5/°C ISO 11359-2 Deflection Temperature Under Load (1.8 MPa) 127 °C ISO 75-1,2 (JIS K7191-1,2) - Electrical Properties
Value Units Test Method / Conditions RTI Elec 80 °C UL 746B RTI Imp 80 °C UL 746B RTI Str 80 °C UL 746B - Optical Properties
Value Units Test Method / Conditions Total Luminous Transmittance 90 % ISO 13468-1 (JIS K7361-1) Refractive Index 1.585 - ASTM D542 - Flammability
Value Units Test Method / Conditions Flammability Rating (0.4 mm (NC)) V2 Class UL 94 - Processing Parameters
Value Units Test Method / Conditions Pre-drying Timings 5.0 - 8 h - Pre-drying Temperature 120 °C - Cylinder Temperature 240 - 260 °C - Mold Temperature 80 - 120 °C -
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability