Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Product Highlights
- The product gives superior protection against stains and has exceptional water resistance.
- It will resist most stains up to 24 hours, however, oils and especially solvents should be wiped up soon after spillage has occurred.
- The product enhances, brightens and beautifies the natural beauty and color of the pavers while improving their durability and resistance to fading.
- Once the surface has been properly cleaned, prepped and dried, the product can be applied immediately after paver installation.
- No waiting period required.
- Features
- Bonds and locks down joint sand.
- Retards efflorescence.
- Prevents ant tunneling.
- Repels oil, grease and rust stains.
- Inhibits weeds and grass between pavers.
- Non- yellowing and UV resistant.
- Easily applied, fast drying and long lasting.
- Interior and exterior use.
- Eases maintenance.
- Re-coatable.
- 25 - 35 % color densification.
- Product Characteristics
- Light Enhancement
- Satin
- Repels Water
- Repels Grease and Oil
- Resists Stains
- Resists Efflorescence
- Resists Spalling
Applications & Uses
- Markets
- Applications
- Application Method
- Compatible Substrates & Surfaces
- Limitations
- Not recommended for pre-sealed surfaces or non-porous surfaces such as ceramic tile, marble, granite, porcelain and terrazzo.
- Do not use where hydrostatic pressure is possible.
- Should not be used in conjunction with polymeric sand.
- Use For
- Segmental Pavement Systems.
- Unglazed Ceramic Tiles - Saltillo.
- Clay Brick and Natural Stone.
- Commercial applications such as parking lots and ports.
- Coverage
- Porous Surface: 75 - 150 sq.ft./gal (flagstone, Mexican clay tile, paver brick, etc.)
- Dense Concrete: 150 - 250 sq.ft./gal (slate, stone, limestone, etc.)
- For exact coverage rates, a measured quantity to proper saturation over a known area will provide a square foot coverage rate for a specific job.
- Clean Up & Remove
- Clean Up: Water
- Remove: Chemical stripper
- Surface Preparation
- Before use on a job, thoroughly test this product on a small area to assure performance and appearance.
- Use only in well ventilated areas. Immediately remove pools or puddles were over application has occurred.
- Cleaning your hardscape project with a pressure washer and/or a surface cleaner is the first step in preparing for a successful project.
- It is strongly recommended to utilize a heated pressure washer to aid in the cleaning process.
- A heated pressure washer in conjunction with Pro Grade Cleaner will remove most organic stains, weeds, and old polymeric sand in considerably less time than it would take with a cold water unit.
- A heated pressure washer will also aid in the removal of residual sealer and decrease the labor when ‘stripping’ old sealer off.
- Stringent cleaners such as muriatic acid can be very harmful to your pavement, causing irreversible damage to the surface.
- Most colorants for concrete are made from iron oxide (FeO2) or better known as rust.
- Strong acids like muriatic acid will dissolve these pigments permanently changing the appearance and etching the surface.
- Allow product to dry thoroughly before applying a sealer.
- Application
- Should not be used in conjunction with polymeric sand as it is also a joint sand stabilizer, not made to activate polymeric sand.
- The product is applied with our Low Volume Pump Sprayer.
- Applying sealer on perimeter edges with a roller is acceptable to eliminate overspray on vegetation and surrounding structures.
- Using the GST Low Volume Pump Sprayer, add sealer up to the top of the GST Logo printed on the sprayer.
- Pump the sprayer approximately 30 times to pressurize the tank. Hold the spray wand 8”-10” from the surface and begin to apply the sealer using an overlapping circular motion to ensure an even application.
- To maintain a consistent even flow of sealer, it will be necessary to continually pump up the sprayer as the pressure in the tank decreases.
- The surface will appear ‘wet-damp’ for 8-10 seconds.
- If you over-apply the sealer and create puddles, it will be necessary to stop spraying and disperse additional sealer on the surface with a blower.
- Back-rolling solvent-based sealers may leave application lines on the surface.
- On segmental pavement systems, application of any sealer with a roller is not recommended as it will pull sand from the joint and will deposit it on the surface causing an undesirable result.
- One coat will seal, protect and enhance the beauty of the surface.
- If a second coat is necessary due to extreme porosity, apply as soon as the first coat is dry to the touch.
- GST sprayers are made with solvent resistant tips and seals, however do not let the sealer dry on the spray tip.
- If this occurs, soak the tip in lacquer thinner. Replacement tips are available.
- Do not apply the product during inclement weather or in direct sunlight when temperatures exceed 80ºF.
- Application to a damp surface or uncured concrete (28 day minimum) may cause a hazy appearance or loss of adhesion.
- Air and surface temperature should be between 50ºF and 80ºF for 24 hours following application.
- On segmental pavement systems, application of any sealer with a roller is not recommended except for the perimeter, as it will pull sand from the joint and will deposit it on the surface causing an undesirable result.
- Use With
- Indoor applications
- Outdoor applications
- Porous Surfaces
- Dense Surfaces
- Concrete, Exposed Aggregate
- Pavers and Slabs
- Brick Masonry
- Natural Stone & Travertine
- Concrete Block Wall
Properties
- Appearance
- Milky but Clear When Dry
- Odor
- Mild Acrylic
- Typical Properties
Value Units Test Method / Conditions VOC 18.0 g/l - Flash Point min. 240 °F - Weight Per Gallon 8.5 Ibs./gal - Package Viscosity (Zahn Cup #2) 27.0 seconds - Solids by Volume 26.0 % - Dry Time 30 - 180 minutes - Cure Time 4 - 7 days - Rainproof 24.0 hours -
Regulatory & Compliance
- Certifications & Compliance
- HMIS Ratings
H - 1; F - 1; R - 0; PP - H
- Compliance
- Meets or exceeds Federal EPA standards for VOC compliance.
- Meets or exceeds South Coast Air Quality Management District and the Bay Area Air Quality Management District, for VOC compliance of less than 100g/l required by the State of California.
Technical Details & Test Data
- Water Penetration Test
- Drop a small amount of water on the sealed surface.
- If water penetration occurs or if water does not bead up on the surface, the application of additional sealer is required.
Safety & Health
- Safety
If on Skin (or Hair):
- Wash with soap and water.
If Inhaled:
- Excessive inhalation of vapors can be harmful.
- Remove person to fresh air and keep comfortable for breathing.
If in Eyes:
- Cause serious eye irritation.
- Immediately flush with plenty of water for at least 15 minutes.
- After initial flushing, remove any contact lenses and continue for at least 15 minutes.
If Ingested:
- May be harmful if swallowed.
- Do not induce vomiting, see a physician.
- Do not handle until all safety precautions have been read and understood.
- Keep away from heat, hot surfaces, sparks, open flames, and other ignition sources.
- No smoking. Ground/bond container and receiving equipment.
- Use explosion-proof electrical ventilating/lighting equipment.
- Use only non-sparking tools. Take precautionary measures against static discharge.
- In case of fire, use the following extinguishing media: foam, CO2, water fog and/or dry chemicals.
- Do not breathe dust, fumes, gas, mist, vapor or spray. Wash thoroughly after handling.
- Use only outdoors or in well ventilated area. Wear protective gloves/protective clothing/eye-face protection.
- Wear an appropriate, properly fitted respirator (NIOSH/MSHA approved) during and after application unless air monitoring demonstrates vapor levels are below applicable limits.
- Follow respirator manufacturer’s directions for use.
- Store in a well ventilated place. Keep container tightly closed. Keep cool.
- Store locked up. Dispose of contents/container according to regional, national and international regulations.
Packaging & Availability
- Available in
- One gallon and five gallon sizes.
- 55 gallon drums and 275 gallon totes are also available upon request.
Storage & Handling
- Storage & Handling
- Storage Temperature: 35 - 120 ° F.
- Shelf Life: Warrantied one year