Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Materials Features
- Properties
- High strength and stiffness
- High impact and notch impact strength
- High heat deflection temperature
- Shock-absorbing properties
- Good sliding and dry running operating features
- Good chemical stability against organic solvents and fuels
- Size alteration by humidity absorption must be considered
- Dimension stability, electrical and mechanical properties may become affected by water absorption
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Applications
- Bearing parts (good sliding properties)
- Gear wheels
- Pump parts
- Sliding rails
- Rollers (reduction of the noise level)
- Fittings
Properties
- Color
- Flame Rating
- Physical Form
- Form and Condition
- Rods. Hollow Bars. Sheets / Solid
- Odor
- Odorless
- Insoluble in
- Water
- Mechanical Properties
Value Units Test Method / Conditions Tensile Strength at Yield 80 MPa ISO 527 Elongation at Break (R) min. 50 % ISO 527 Impact Strength (an) No break kJ/m2 ISO 179 Notch impact Strength (ak) min. 4 kJ/m2 ISO 179 Ball Indentation (Rockwell Hardness) 160 MPa ISO 2039 Hardness 83 Shore D ISO 868 Flexural Strength (B 3,5 %) min. 100 MPa ISO 178 Modulus of elasticity (Et) 3100 MPa ISO 527 - Physical Properties
Value Units Test Method / Conditions Specific Gravity 1.15 - ISO 1183 Water Absorption 6.5 % ISO 62 Humidity Absorption 2.2 % ISO 62 Maximum Permissible Service Temperature 105 °C UL746B Lower Permissible Service Temperature -40 °C UL746B - Thermal Properties
Value Units Test Method / Conditions Coefficient of Linear Thermal Expansion min. 0.8 K-1.10-4 ISO 11359 Thermal Conductivity (20°C) 0.23 W/(m.K) ISO 22007-4 Glass Transition Temperature (Tg) 40 °C ISO 3146 Melting Temperature (Tm) 220 °C ISO 3146 - Typical Properties
Value Units Test Method / Conditions Density 1.15 g/cm³ - Melting Temperature (ca) 220 °C - Thermal Decomposition (ca) 300 °C - Ignition Temperature (ca) 450 °C - - Electrical Properties
Value Units Test Method / Conditions Volume Resistivity min. 10^13 Ω.cm IEC 60093 Surface Resistivity (Ro) min. 10^13 Ω IEC 60093 Dielectric Constant (1MHz) 3.7 - IEC 60250 Dielectric Loss Factor (1 MHz) 0.03 - IEC 60250 Dielectric Strength 50 kV/mm IEC 60243-1 Tracking Resistance CTI 125 V IEC 60112 Tracking Resistance CTI 600 V IEC 60112 - Additional Information
Value Units Test Method / Conditions Bondability Yes - - Physiological Indifference (EEC) Yes - - Physiological Indifference Yes - EEC Flammability V-0 - UL 94 Flammability HB - UL 94 Physiological Indifference (FDA) Limited - - Limiting Oxygen Index (LOI, 9) 35 % ASTM D2863 UV Stabilisation (6, 9) Limited - -
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Fire-fighting Measures
Suitable extinguishing agents
Water, foam, dry chemical, carbon dioxide (CO2).
Potential combustion products
Carbon dioxide (CO2), carbon monoxide (CO). Formation of further decomposition and oxidation products depend upon the fire conditions. Under special fire conditions traces of other toxic substances are possible.
Special protective equipment
Wear a self-contained breathing apparatus. If exposed to combustion fumes bring the victim into fresh air.
Further information
Dispose of fire debris and contaminated extinguishing water in accordance with official regulations..
Safety & Health
- Safety Measures
The general industrial safety measures should be considered. A thermal damage during machining should be avoided.
Storage & Handling
- Machining
The product can be machined with standard machinery and tools. Before machining the product should be stored at room temperature 24 h. Evacuate swarf to prevent slipping or tripping. Observe the maximum allowable concentration of dust levels on the working area which apply in your country. Wear safety goggles during machining. General dust limit value: Respirable dust (6 mg/m3); Inhalable dust (10 mg/m3).
- Storage
The products shall be stored indoor to keep away from any source of degradation such as sunlight, UV-jets, ionizing radiation, chemicals.