Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Additives Included
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- DC Cables Application Data
Details
DC Cables are generally used for standard electronics charging systems, like adapters. The latest designs can also be used for USB-C charging, leading to much thinner cables than AC with similar charging and safety characteristics.
Benefits
- Arnitel® has a proven track record in wire and cable, also in ultra thin cables in all application areas
- Arnitel® offers a long history in commercial production and use in major electronics OEM
- Arnitel® solutions are known to most cable extrusion companies
- Arnitel® is easy to color with consistent haptics
- AC Cables Application Data
Details
AC UL jacket is for the American standard markets, whereas the AC EU jacket is suitable for (low smoke) EU markets. The AC insulation solutions are the most robust in class. The AC Power Plug utilizes the optimum performance of the jacket materials with injection molding characteristics.
Benefits
- Arnitel® has a 10 year track record in AC cables
- Arnitel® offers consistent FR performance
- Arnitel® allows coloring in virtually any color possible
- Arnitel® is suitable for indoor and outdoor
- Arnitel® offers the most flexible solution in its class
Properties
- Thermal Properties
Value Units Test Method / Conditions Melting Temperature (10°C/min) 195 °C ISO 11357-1/-3 Glass Transition Temperature (at 10°C/min) -70 °C ISO 11357-1/-2 - Electrical Properties
Value Units Test Method / Conditions Volume Resistivity 8.3E10 Ohm*m IEC 62631-3-1 Electric Strength 19.8 kV/mm IEC 60243-1 - Other Properties
Value Units Test Method / Conditions Water Absorption 0.2 % Sim. to ISO 62 Humidity Absorption 0.65 % Sim. to ISO 62 Density 1130 kg/m³ ISO 1183 - Mechanical Properties (TPE)
Value Units Test Method / Conditions Tensile Modulus 60 MPa ISO 527-1/-2 Stress at 10% strain 3.5 MPa ISO 527-1/-2 Stress at 100% strain 5.3 MPa ISO 527-1/-2 Stress at Break 10.6 MPa ISO 527-1/-2 Nominal Strain at Break 440 % ISO 527-1/-2 Shore A Hardness (3s) 88 - ISO 868 - Rheological Properties
Value Units Test Method / Conditions Melt Volume-Flow Rate (at 280 °C, 2.16 kg) 4.3 cm³/10min ISO 1133
Regulatory & Compliance
- Certifications & Compliance
- Quality Standards
Technical Details & Test Data
- Chemical Resistance
Chemical Type Chemical Name Resistance Other Acetic acid (10% by mass) at 23°C resistant Ketones Acetone at 23°C resistant Other Ammonium hydroxide (10% by mass) at 23°C limited resistant, tests necessary to verify Other ASTM 1 at 23°C resistant Other ASTM 3 at 23°C resistant Other Brake fluids (DOT 3/4) at 23°C not resistant Other Calcium chloride (10% by mass) at 23°C limited resistant, tests necessary to verify Other Chloroform at 23°C not resistant Ethers Diethyl ether at 23°C limited resistant, tests necessary to verify Alcohols Ethanol at 23°C limited resistant, tests necessary to verify Other Ethyl Acetate at 23°C limited resistant, tests necessary to verify Other Fuel; Diesel at 85°C resistant Other Hydrochloric acid (10% by mass) at 23°C resistant Other Hydrogen peroxide (30% by mass) at 23°C limited resistant, tests necessary to verify Other Nitric acid (10% by mass) at 23°C resistant Other Phosphoric acid (10% by mass) at 23°C resistant Other Sodium hydroxide (10% by mass) at 23°C resistant Other Sulfuric acid (30% by mass) at 23°C resistant Other Tetrachloroethylene at 23°C limited resistant, tests necessary to verify Hydrocarbons Toluene at 23°C resistant Other Transformer oil at 23°C not resistant Other Trichloroethylene at 23°C not resistant Other Water at 23°C resistant Other Zinc chloride (10% by mass) at 23°C resistant