Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
- Product Families
Features & Benefits
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Medical Tubes Application Data
Details
Arnitel® Care \is also being used for medical wound dressings.Benefits
- Arnitel® TPC allows for reliable solutions in respiratory tubing due to its excellent breathability, preventing condensation
- Arnitel® TPC allows for light weight solutions as compared to silicone alternatives
- Respiratory Tubes Application Data
Details
Respirator tubing is both used in monowall and in spiralized reinforced designs.
Benefits
- Arnitel® has USP class VI and FDA approved grades available
- Arnitel offers a good combination of flexibility, strength and kink resistance
- Arnitel has high breathable grades available to prevent condensation inside the tube
Properties
- Mechanical Properties
Value Units Test Method / Conditions Yield Stress 14 MPa ISO 527-1/-2 Yield Strain 20 96 ISO 527-1/-2 Flexural Modulus 180 MPa ISO 178 Charpy Impact Strength (at +23°C) N kJ/m2 ISO 179/1eU Charpy Impact Strength (at -30°C) N kJ/m ISO 179/1eU Charpy Notched Impact Strength (at +23°C) N kJ/mº ISO 179/leA Charpy Notched Impact Strength (at -30°C) 25 kJ/m2 ISO 179/leA - Thermal Properties
Value Units Test Method / Conditions Melting Temperature (at 10°C/min) 207 °C ISO 11357-1/-3 Vicat Softening Temperature (50°C/h 50N) 90 c ISO 306 Coefficient of Linear Thermal Expansion (parallel) 1.5 E-4/°C ISO 11359-1/-2 Coefficient of Linear Thermal Expansion (normal) 1.5 E-4/°C ISO 11359-1/-2 Burning Behaviour (at 1.5 mm Nominal Thickness) UL HB class IEC 60695-11-10 Relative Temperature Index (Electrical, 1.5 mm) 50 C UL746B Relative Temperature Index (with impact, 1.5 mm) 50 -C UL746B Relative Temperature Index (without impact, 1.5 mm) 50 -C UL746B - Electrical Properties
Value Units Test Method / Conditions Relative Permittivity (100Hz) 4.4 - IEC 62631-2-1 Relative Permittivity (1 MHz) 4 - IEC 62631-2-1 Dissipation Factor (1 MHz) 400 E-4 IEC 62631-2-1 Volume Resistivity 100000000000 Ohm'm IEC 62631-3-1 Electric Strength 21 kV/mm IEC 60243-1 - Other Properties
Value Units Test Method / Conditions Water Absorption 0.65 % Sim. to ISO 62 Humidity Absorption 0.2 % Sim. to ISO 62 Density 1200 kg/m ISO 1183 - Mechanical Properties (Die Cutting)
Value Units Test Method / Conditions Stress at Break (normal) 41 MPa ISO 527-1/-2 Strain at Break (normal) 820 96 ISO 527-1/-2 Tear Strength (normal) 125 kN/m ISO 34-1; Method B Tear Strength (parallel) 134 kN/m ISO 34-1; Method B - Mechanical Properties (TPE)
Value Units Test Method / Conditions Tensile Modulus 175 MPa ISO 527-1/-2 Stress at 5% strain 7 MPa ISO 527-1/-2 Stress at 10% strain 11 MPa ISO 527-1/-2 Stress at 50% strain 14 MPa ISO 527-1/-2 Stress at 100% strain 14 MPa ISO 527-1/-2 Strain at Break min. 300 % ISO 527-1/-2 Nominal Strain at Break 420 % ISO 527-1/-2 Compression Set Under Constant Strain (at 70°C) 40 % ISO 815 Shore D Hardness (35) 52 - ISO 868 - Rheological Properties
Value Units Test Method / Conditions Melt Volume-Flow Rate (at 230°C, 2.16kg) 9 cm/10min ISO 1133
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Chemical Resistance
Chemical Type Chemical Name Resistance Other Acetic acid (10% by mass) at 23°C resistant Ketones Acetone at 23°C resistant Other Ammonium hydroxide (10% by mass) at 23°C limited resistant, tests necessary to verify Other ASTM 1 at 23°C resistant Other ASTM 3 at 23°C resistant Other Brake fluids (DOT 3/4) at 23°C not resistant Other Calcium chloride (10% by mass) at 23°C limited resistant, tests necessary to verify Other Chloroform at 23°C not resistant Ethers Diethyl ether at 23°C limited resistant, tests necessary to verify Alcohols Ethanol at 23°C limited resistant, tests necessary to verify Other Ethyl Acetate at 23°C limited resistant, tests necessary to verify Other Fuel; Diesel at 85°C resistant Other Hydrochloric acid (10% by mass) at 23°C resistant Other Hydrogen peroxide (30% by mass) at 23°C limited resistant, tests necessary to verify Other Nitric acid (10% by mass) at 23°C resistant Other Phosphoric acid (10% by mass) at 23°C resistant Other Sodium hydroxide (10% by mass) at 23°C resistant Other Sulfuric acid (30% by mass) at 23°C resistant Other Tetrachloroethylene at 23°C limited resistant, tests necessary to verify Hydrocarbons Toluene at 23°C resistant Other Transformer oil at 23°C not resistant Other Trichloroethylene at 23°C not resistant Other Water at 23°C resistant Other Zinc chloride (10% by mass) at 23°C resistant - Shearstress-Shear Rate
- Viscosity-Shear Rate
Packaging & Availability
- Packaging Type