Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Cure Method
Properties
- Typical Properties
Value Units Test Method / Conditions Conductivity max. 30 ohms/sq/mil - Viscosity 30,000 - 35,000 cps - Filler Carbon - - Crease Resistance 0.075 - - Sheet Resistivity 30 Ω/sq/mil - Hydrolytic Stability Excellent - - Useful Temperature Range -55 to 120 ºC -
Regulatory & Compliance
- Certifications & Compliance
Safety & Health
- Safety & Handling
- Use with adequate ventilation.
- Keep away from sparks and open flames.
- Avoid prolonged contact with skin and breathing of vapors.
- Wash with soap and water to remove from skin.
- Xylene works especially well as a cleanup solvent
Storage & Handling
- Shelf Life
- 12 months at -10°C., 6 months at 25°C, 9 months at -5°C
- Suggested Handling & Curing
128-07 is ready to use as supplied. Further thinning may be accomplished by adding small amounts of CMI thinner 102-03 or 127-17. Prior to use, be certain to mix well to re-suspend filler. Best properties for most applications result when cured for 5 to 10 minutes at 175°C. Excellent properties are also obtained on a variety of substrates by curing at temperatures ranging from 50°C to 180°C. End user is advised to experimentally determine temperature and time best suited for individual applications.