SuperSeal™ 2000

SuperSeal™ 2000 is an acrylic-based, crystal-clear sealer. Formulated and recommended for application to a porous substrate for the primary purpose of preventing the penetration of water. It is a premium-quality, non-yellowing, UV resistant, super-tough acrylic film that is easy to clean and maintain. It is formulated and recommended for application to a porous substrate for the primary purpose of preventing the penetration of water.

Brand: SuperSeal (2 products)

Product Type: Sealer

Compatible Substrates & Surfaces: Concrete

Features: Consistent High Quality, Excellent Transparency Properties, Glossy Surface Aspects, Good Non-Yellowing Properties, Good Toughness, Good UV Resistance

Application Method: Roller, Spray

Chemical Family: Acrylics & Acrylates

Enhanced TDS

Knowde-enriched technical product data sheet

Identification & Functionality

Features & Benefits

Ready-to-Use Product Features
Features

Non Yellowing, Crystal Clear Dries to a Gloss "Wet Look" Finish Interior/Exterior Use- Enhances Color.

Applications & Uses

Markets
Applications
Application Method
Compatible Substrates & Surfaces
Uses

SuperSeal™ 2000 can be used on interior or exterior masonry, and concrete-type surfaces. SuperSeal™ 2000 can be used as a base-coat for interior applications where a compatible, commercial floor waxes is planned as part of a maintenance program. Use on colored or uncolored, stamped or exposed aggregate concrete, porous brick, natural and manufactured stone, stucco, slate, unglazed tile and flagstone.

Application

Always test a small area of surface to verify protection and appearance. Use SuperSeal TM 200o full strength. Thinning is not required. Apply 1-2 light, even coats (depending on porosity of surface) with a short-napped roller or a sprayer with neoprene seals and hose. Allow 1-3 hours between coats or until the surface is dry to the touch. Apply in temperatures between 12.8°C to 26.7°C (s5°F and 80°F). Avoid using in direct sunlight, especially on hot, windy days. Apply during the cooler part of the day when the surface is shaded. Do not apply on rainy or foggy days. moisture will not allow the sealer to dry properly. Use only in well ventilated areas. It is recommended that foot traffic Excess remain off the finished sealed surface for 24 hours. For heavy traffic, allow 72 hours for curing. HELPFUL HINT: Use xylene for easy cleanup immediately after use.

Maintenance

The sealed surface should be inspected periodically for areas of thin or traffic-worn sealer and reapplied as needed. If traces of efflorescence are present, it should first be eliminated with a gentle deaner. expectancy. routinely sweep and wash floors appropriate cleaners and detergents. All chemicals or abrasive grit should be removed as soon as possible.

Coverage

Superseal 2000 will cover approximately 150 to 200 square feet per gallon depending upon porosity of the surface.

Cautions

Contains aromatic hydrocarbons. Keep out of reach of children. Before using or handling, read the material safety data sheet and warranty. Internally. Do not breathe vapors or mist. Use only with adequate ventilation and use a respirator when levels are above applicable limits. Eyes. Close container after each use. Use good hygiene when handling this product and wash and bathe after each use. Be sure to wash clothing after each use. Do not take avoid contact with skin

Warning

It is illegal to use this product in the state of california. Other states may also have similar restrictions. Check with your local not recommended for regulatory agency. Dense surfaces. Apply in thin coats, only on surfaces textured for slip resistance. If applied too heavily or applied to dense surfaces, the sealer may become slippery, especially in areas where water accumulates. If in doubt, test the surface by sprinkling with water. If water beads up on the surface, additional cleaning and testing must be done. Do not use where hydrostatic pressure is possible.

Prepartion Of Concrete

Concrete Coatings, Inc. strongly recommends representative jobsite samples. work should test different sections of the concrete to Individuals who will be performing the determine suitability, coverage, and final appearance. New concrete should be cured at least 28 days, prior to application. The application area must be completely clean and dry to the touch. scrubbing may be necessary. Remove all efflorescence, oil, dirt, wax, old paints, sealer, and curing compounds. RINSE THOROUGHLY. Allow the surface to dry at least 24 hours. Pressure washing and power. Soaps and detergents should never be used for cleaning. Dried residue on the surface will prevent the sealer from bonding. Acid washing is NOT recommended. If acid is used, a representative area must be tested. Soak the entire surface with water before applying the acid mixture. When the fizzing stops, rinse with clean water. After 10 or 15 minutes, the surface must then be flushed with clean water and neutralized with a pH neutralizer such as ammonia, baking soda, or T.S.P. Repeat rinsing and neutralizing. Acid residue will prevent the sealer from penetrating. Allow the surface to dry for at least 24 hours prior to application. NOT RECOMMENDED for pre-sealed or dense surfaces, such as glazed tile, marble or granite, dense brick, dense slate, or terrazzo. If in doubt, test the surface by sprinkling with water. If water beads up on the surface, additional cleaning and testing must be done. Do not use where hydrostatic pressure is possible.

Plan Specification

SuperSeal 2000 Suggested Short Form Specification: All concrete flatwork designated as being sealed in the plans and specifications shall be sealed with 1-2 light even coats of Superseal 2000, at the rate of approximately 250 to 300 square teet per gallon (6.13-7.36 m/L), manutactured by CCI 8o0-443 2871, Layton, UT. Superseal 2000 shall be applied in accordance with the SuperSeal 2000 Technical Intormation Sheet.

Properties

Typical Properties
ValueUnitsTest Method / Conditions
Moisture Retention (Super Seal 2000 , At 200 ft² per gallon)0.21kg/m²Test ASTM C309
Moisture Retention (Test requirement, not to exceed)0.55kg/m²Test ASTM C309
Moisture Retention (Super Seal 2000 , At 300 ft² per gallon)0.32kg/m²Test ASTM C309
Moisture Retention (Test requirement, not to exceed, 300 ft² per gallon)min. 0.4kg/m²Test ASTM C309
Gasoline Resistance (15-minute exposure, ponding)Slight dulling--
Tg50.0°C-
Tukon Hardness (30 minutes at 180°F)9.3--
Tukon Hardness (30 minutes at 300°F)13.7--
Pencil Hardness (30 minutes at 180°F)F--
Pencil Hardness (30 minutes at 300°F)H--
Abrasion resistance (Lost, CS-17 wheel, 1000 g load, 1000 cycles)160.0mg-
Flexibility (1/8 inch mandrel)6.0--
Flexibility (1/4 inch mandrel)5.0--
Flexibility (1/2 inch mandrel)4.0--
Spray conditions (Viscosity, No. 2 Zhan cup)19.0sec-

Packaging & Availability

Packaging Type
Available in

One gallon (3.8 L) and five-gallon (18.925 L) containers and fifty-five gallon (208.175 L) drums.

Order Specification
Shipping Weight: 8 lbs (3.63 kg) Container Size: 1-Gallon (3.785 L)

Item No: S-DRILK-1

Shipping Weight: 40 lbs (18 kg) Container Size: 5-Gallon (18.925 L)

Item No: S-DRILK-5

Shipping Weight: 450 lbs (202.5 kg) Container Size: 55-Gallon (208.175L)

Item No: S-DRILK-55

Storage & Handling

Storage

Store in a safe place. Keep containers tightly sealed. DO NOT allow product to freeze. Material that is froz CANNOT be used when thawed. Shelf life is approximately 12 months.