Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Carrier
- Chemical Family
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Benefits
- Increases useful life of concrete structures
- Low-cost, easy to handle and apply
- Resists many acids, oils, greases and salts
- Reduces porosity and permeability and increases hardness which results in better wear resistance
- Prevents rebar corrosion
- Ideal for enclosed food preparation areas where odors and toxic fumes can be absorbed by food.
- Purges soluble chlorides and prevents reentry
- Does not effloresce like traditional silicate sealers
- Contains a proprietary penetrating agent
- Does not alter bondability of concrete
- Clean Up
- Rinse equipment with cold water. If CP-1007 is accidentally sprayed on glass, aluminum, ceramics, glazed tiled etc. rinse with clear water immediately.
Applications & Uses
- Markets
- Applications
- Application Area
- Application Method
- Compatible Substrates & Surfaces
- Applications
CP-1007 has been used to treat concrete walls, storage tanks, and building blocks. Roadways, driveways, runways, warehouse floors, industrial plants, food processing plants and hospitals. CP-1007 also reduces vapor emissions for application of surface coatings such as polyurea, epoxy, urethane, as well as carpet, floor tile, sheet vinyl and hardwood flooring materials.
- Limitations
Do not dilute or alter. Application temperature range 35º - 120ºF (2º - 49ºC). Protect from freezing. However, may be reused after thawing and agitation
Avoid contact with glass, aluminum, ceramics, glazed tile and wood.
Carbonated concrete should be abraded prior to application.- Drying
CP-1007 penetrates in approximately thirty (30) –sixty (60) minutes dependiing on temperature and humidity. Allow each application to penetrate thoroughly before proceding with additional applications.
Allow twenty four hours afte application before opening to wheeled traffic.Following drying, gloss development can be enhanced by buffing and or additional floor scrubbing.
Properly treated concrete may be painted without any difficulty. However there should be no CP-1007 residue on the surface prior to painting. Washing with hot water will remove the alkalinity that may be due to the silicate. An alkali-resistant paint should be used.Properly treated concrete may be painted without any difficulty. However there should be no CP-1007 residue on the surface prior to painting. Washing with hot water will remove the alkalinity that may be due to the silicate. An alkali-resistant paint should be used.
Properties
- Color
- Physical Form
- Odor
- None
- Typical Properties
Value Units Test Method / Conditions pH 11 - -
Regulatory & Compliance
- Chemical Inventories
Technical Details & Test Data
- Coverage
Rough Slab Finish:
50 – 100 sq ft/galDense and Smooth Finish
100 – 150 sq ft/galFollow recommended coverage rate guidelines.
- Installation
New Concrete:
Apply CP-1007 undiluted to finished, damp concrete surface with low pressure sprayer after all surface water has evaporated and the surface will not be damaged or blemished by the application procedure.
Keep the treated surface area wet with CP-1007 for thirty (30) minutes by spraying additional product and/or brooming excess materia. Do not allow dry spots to occur. Prevent drying of surface for twenty (20)-thrity (30) minutes.As CP-1007 begins to penetrate and react, mist the surface lightly with clean water and brush, broom or scrub with non-aggresive brush or pad into surface to aid penetration/reaction.
After thrity (30) minutes, depending on temperature and humidity, CP-1007 will begin to gel. Keep all treated surfaces moist, and continue brushing/scrubbing action for 5-15 minutes. Note: Surface can be slippery.
Flush the surface with water and squeegee to remove excess material and all impurities present on the surface. Rinse with generous amounts of water to enhance product performance. Finish with a damp mop. CP-1007 is environmantaly safe and may be flushed directly into drains.
DO NOT allow CP-1007 residue to dry on the surface. Any product allowed to dry on the surface may cause white residue that can be difficult to remove.- Existing Concrete
For best results, apply to concrete cured seven (7) days or longer.
Assure surface is clean and free of contaminants (waxes, curing membrane, oil, etc). The surface must be thoroughly cleaned and swept with a broom to remove any loose dirt. It should then be wetted and scrubbed with Terazyme GP cleaner/degreaser or other cleaning compound. The abrasive action removes the film of consolidated dirt and exposes the true wearing surface. The surface should then be scrubbed, again, with soapy water and flushed with fresh water. To get the best penetration the floor should be allowed to dry thoroughly for a minimum of 24 hours, depending on atmospheric humidity.
The surface being treated should be pre-dampened prior to application of the sealer. Apply undiluted CP-1007 to saturation level by sprayer, broom, squeegee or floor scrubber.
Keep the treated surface area wet with product for thirty (30) minutes by spraying additional product and/or brooming excess material from low areas.
Do not allow dry spots to occur. Prevent any drying of surface for twenty (20) to thirty (30) minutes. Use brooms or floor scrubber with non-aggresive pad or brushes to aid in penetration.
After twenty (20) to thirty (30) minutes, depending on temperature and humidity, CP-1007 will begin to gel. Keep all treated surfaces moist, and continue brushing/scrubbing action for 5-15 minutes. Note: Surface can be slippery.