Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- Product Type
- Chemical Class
- UV Acrylate
- Cleanup Solvent
- Isopropyl alcohol
- Technologies
- Product Families
- Substrate
- Plastics
- Glass
- Metals
Features & Benefits
- Ready-to-Use Product Features
- Features
- RoHS & REACH Compliant
- GB 33372-2020 Compliant
- Non-Yellowing, No-Haze
- Low Stress Adhesive
- Ultra -Low Shrinkage
- UVV Curable
Applications & Uses
- Markets
- Applications
- Application Area
- Compatible Substrates & Surfaces
- Cure Method
- Application
- Touch Screen Displays
- LCD
- Large Format Displays
- Consumer Displays
- Medical Devices
- UV Curing Guidelines*
Humiseal Vivid CureTM UV 7041 adhesive has been formulated to allow flexibility in the curing process. Humiseal Vivid CureTM UV 7041 can be cured using 395nm LED systems. The table below details minimum dosage values required to properly crosslink Humiseal Vivid CureTM UV 7041.
“Note, adhesive thickness range of 700 – 750 microns was used during the development of the minimum required dosage values recommended below. If a different adhesive thickness is used, process adjustments may be required.”Vivid CureTM UV 7041 Recommended Minimum Dose (J/cm2) Requirements Wavelength (nm) 395nm UVV 5 Values measured with an EIT Powerpuck II
Properties
- Physical Form
- Appearance
- Clear
- Typical Properties
Value Units Test Method / Conditions Viscosity ( 25°C, Spindle 5 @ 20 RPM) 2,000 - 3,000 cPs - Specific Gravity 0.9 - - Tensile Modulus (-60°C) 100 - 500 MPa - Glass Transition Temperature (Tg) -40 to -45 °C - Linear Shrinkage max. 1 % - Refractive Index 1.459 - 1.470 - - Haze max. 0.2 % ASTM D1003 Total Luminous Transmittance max. 99 % per ASTM D1003 Color Coordinate, b* 0.03 - - Dielectric Constant / Dissipation Factor (200 KHz) 2.94 / 0.045 - - Dielectric Constant / Dissipation Factor (400 KHz) 2.65 / 0.044 - - Dielectric Constant / Dissipation Factor (800 KHz) 2.86 / 0.042 - - Dielectric Constant / Dissipation Factor (1 MHz) 2.79 / 0.046 - - Operating Temperature Range -50 to 125 °C -
Regulatory & Compliance
- Certifications & Compliance
Storage & Handling
- Storage
Humiseal Vivid CureTM UV 7041 should be stored between 8°C - 28°C in tightly closed, light-blocking containers, away from direct sunlight. Keep from freezing. Allow material to equilibrate to process area temperature for 24 hours before use. Please refer to product labeling for shelf-life information. While the material can be heated to facilitate degassing prior to use, this operation should be conducted only on the amount of adhesive to be immediately used. Multiple heating cycles of the bulk container or elevated temperature storage of Humiseal Vivid CureTM UV 7041 should be avoided. Consult SDS for full safety information.