Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Chemical Family
- CASE Ingredients Functions
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- CASE Ingredients Features
- Performance Highlights
UCECOAT 7850 is characterized by:
- translucent appearance
- low viscosity
- tack free-property before cure, after water evaporation
UV/EB cured products based on UCECOAT 7850 are characterized by the following performance properties:
- high flexibility
- high hardness
The actual properties of UV cured products also depend on the selection of the other formulation components, such as reactive diluents, additives and photoinitiators.
Applications & Uses
- Markets
- Applications
- Application Method
- Compatible Substrates & Surfaces
- Cure Method
- Coating Type
- Recommended Uses & Known Applications
- Formulated UV curable products containing UCECOAT 7850 may be applied by spray- and curtain coating methods.
- UCECOAT 7850 is recommended for use in wood coatings
Properties
- Physical Form
- Appearance
- Translucent liquid
- Physical Properties
Value Units Test Method / Conditions Density 1 g/cm³ - Particle Size max. 100 nm - Polymer Solids Content 35 wt% - pH Value 44780 - - - Typical Properties
Value Units Test Method / Conditions Brookfield Viscosity (at 25°C) max.200 mPa.s -
Safety & Health
- Precautions
- The following is a summary of the precautions to be taken when handling this product. Please refer to the Safety Data Sheet for further details.
- The toxicological properties of this material have not been fully determined. Products of this type can be expected to be eye and skin irritant and have the potential to cause sensitization or other allergic responses. Appropriate precautions should be taken to avoid eye and skin contact and to avoid inhalation of the aerosols or vapors.
- Consult the relevant Safety Data Sheet for appropriate handling procedures and protective equipment prior to using this or any other material referred to in this bulletin.
- See Safety Data Sheet for emergency and first aid procedures.
Packaging & Availability
- Regional Availability
Storage & Handling
- Storage and Handling
Care should be taken not to expose radiation curable products to temperatures exceeding 40°C for prolonged periods or to direct sunlight. This might cause uncontrollable polymerization of the product with generation of heat. Due to presence of water, UCECOAT 7850 needs to be stored above freezing temperatures.
Storage and handling should be in stainless steel, amber glass, amber polyethylene or baked phenolic lined containers. Do not store this material under an oxygen free atmosphere. Use dry air to displace material removed from the container.
This material should not be stored for more than 1 year.