Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Backing Material Type
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Key Attributes
- Biocompatible
- Non-irritating, non-toxic
- Excellent adhesion to low surface energy plastics
- Excellent adhesion to medical fabrics, such as nonwovens
- Suitable for active lifestyles with being breathable and water resistant
Applications & Uses
- Markets
- Applications
- For Best Results
- The surfaces you wish to bond should be clean and free of oil, moisture and dust. If the surface temperature is below 40°F, it may be difficult to achieve a proper bond.
- Do not use a pressure-sensitive adhesive product where it will be exposed to temperatures lower or higher than those designated for each product. Heat can destroy the effectiveness of the bond and extreme cold can cause the adhesive to harden and not adhere properly.
- When the tape is applied, use firm hand or lamination pressure to achieve contact between the adhesive and the surface to which it is applied. Hand rollers or nip rollers may be needed for certain products or applications.
Consult your AR sales representative if you need additional information.
- Applications
The typical use for this product is to adhere medical devices to skin tapes.
Properties
- Typical Properties
Value Units Test Method / Conditions Peel Adhesion on Stainless Steel (AS-203 side) 21.5 N/25mm 180 degrees, 12 ipm, 5 min. dwell Peel Adhesion on Stainless Steel (MA-69 side) 15.2 N/25mm 180 degrees, 12 ipm, 5 min. dwell Moisture Vapor Transmission Rate 200.0 g/m²/day Payne Cup Method Recommended Storage of Unconverted Product (50% ± 20% RH ) 21 ± 11 °C - Non-Woven Basis Weight (White non-woven carrier) 8 gsm - Release of 2 mil Clear S/F Liner 46.0 g/2” 180 degrees, 300 ipm Release of 2 mil White D/F Liner 43.0 g/2” 180 degrees, 300 ipm AS-203 Side, Peel Adhesion on Stainless Steel (180 degrees, 12 ipm, 5 min. dwell) 21.5 N/25mm - MA-69 Side, Peel Adhesion on Stainless Steel (180 degrees, 12 ipm, 5 min. dwell) 15.2 N/25mm - Release of 2 mil White D/F Liner (180 degrees, 300 ipm) 43 g/2” - Release of 2 mil Clear S/F Liner (180 degrees, 300 ipm) 46 g/2” - MVTR (Moisture Vapor Transmission Rate) 200 g/ m2/ day Payne Cup Method
Technical Details & Test Data
- Product Construction
Typical Values Description Liner thickness 2.0 mil 51 μm D/F, white PET release liner Adhesive thickness 1.6 mil 41 μm AS-203, acrylic adhesive, skin tape side Non-woven basis weight 8 gsm White non-woven carrier Adhesive thickness 1.3 mil 33 μm MA-69, acrylic hybrid adhesive, device side
Liner thickness 3.0 mil 76 μm S/F, Clear PET release liner Total thickness 3.9 mil 99 μm (Excluding liners) - Note
- All stated values are nominal and should only be used as a guide for selection. They are not specifications. The information contained on this data sheet is based upon test results of limited quantities of this material and may be modified by Adhesives Research following additional production experience and evaluation. This data should not be used in preparing specifications. Products identified as developmental may be subject to modification by Adhesives Research, Inc.
Storage & Handling
- Shelf Life
- 18 Months
- Shelf life of Unconverted product
- Not to exceed 18 months from date of manufacture
- Storage of Pressure-Sensitive Adhesive Tapes
- Pressure-sensitive adhesive tapes function as a mechanical product however, the adhesive itself is a chemical composition that can be sensitive to environmental conditions. A purchaser of pressure-sensitive adhesive products should be aware of the shelf life of each product and not purchase more than it can use before the expiration date. Shipping and storage conditions affect shelf life. The optimum storage temperature is 70 °F (21 °C). Cool, dry storage is recommended.
- Recommended Storage of Unconverted Product
- 21 ± 11 °C (50% ± 20% RH)