Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Backing Material Type
- Carrier
- Product Type
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Ready-to-Use Product Features
- Key Attributes
- Excellent adhesion on skin for long-term wear
- High moisture vapor transmission
- Water resistance
- Biocompatible per ISO 10993
- Facilitates design options
- Residue-free removal
Applications & Uses
- Markets
- Applications
- Application Area
- For Best Results
- The surfaces you wish to bond should be clean and free of oil, moisture and dust. If the surface temperature is below 40°F, it may be difficult to achieve a proper bond.
- Do not use a pressure-sensitive adhesive product where it will be exposed to temperatures lower or higher than those designated for each product. Heat can destroy the effectiveness of the bond and extreme cold can cause the adhesive to harden and not adhere properly.
- When the tape is applied, use firm hand or lamination pressure to achieve contact between the adhesive and the surface to which it is applied. Hand rollers or nip rollers may be needed for certain products or applications.
Consult your AR sales representative if you need additional information.
- Applications
The typical use for this product is bonding on skin for long-term wear applications including adhesion of wearable load-bearing devices on skin.
Properties
- Color
- Typical Properties
Value Units Test Method / Conditions Moisture Vapor Transmission Rate 550.0 g/m²/day ART4047 Moisture Vapor Transmission Rate 550 g/m²/day Payne Cup Method Peel Adhesion on Stainless Steel 9.75 N/25mm 90 degrees, 12 ipm, 15 minute dwell Recommended Storage of Unconverted Product (50% ± 20% RH ) 21 ± 11 °C - Release of Polyester Liner ~160 g/2” 90 degrees, 12 ipm Static Shear ~35 min 500 g, ½” x ½” Peel Adhesion on Stainless Steel (90 degrees, 12 ipm, 15 minute) 9.7 N/25mm - Release of Polyester Liner (dwell) approx. 160 g/2” - Static Shear (500 g, ½” x ½”) approx. 35 minute -
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Product Construction
Typical Values Description Carrier thickness 7.0 mil 178 μm White PU non-woven carrier Adhesive thickness 2.6 mil 66 μm MA-91 medical grade adhesive Liner thickness 2.0 mil 50 μm Clear polyester liner Total thickness 9.6 mil 244 μm (Excluding liner) - Note
- All stated values are nominal and should only be used as a guide for selection. They are not specifications. The information contained on this data sheet is based upon test results of limited quantities of this material and may be modified by Adhesives Research following additional production experience and evaluation. This data should not be used in preparing specifications. Products identified as developmental may be subject to modification by Adhesives Research, Inc.
Safety & Health
- Safety Data
- MA-91 is a medical grade adhesive. The adhesive passed cytotoxicity, primary skin irritation, and skin sensitization tests conducted by an independent laboratory. Additional safety information is available upon request.
Storage & Handling
- Shelf Life
- 1 Year
- Shelf life of Unconverted product
- Not to exceed one year from date of manufacture
- Storage of Pressure-Sensitive Adhesive Tapes
- Pressure-sensitive adhesive tapes function as a mechanical product however, the adhesive itself is a chemical composition that can be sensitive to environmental conditions. A purchaser of pressure-sensitive adhesive products should be aware of the shelf life of each product and not purchase more than it can use before the expiration date. Shipping and storage conditions affect shelf life. The optimum storage temperature is 70 °F (21 °C). Cool, dry storage is recommended.
- Recommended Storage of Unconverted Product
- 21 ± 11 °C (50% ± 20% RH)