Enhanced TDS
Knowde-enriched technical product data sheet
Identification & Functionality
- Additives Included
- Chemical Family
- Polymer Name
- Technologies
- Product Families
Features & Benefits
- Labeling Claims
- Materials Features
- Fire Resistance
Halogen and antimony free
Polyamid 6 halogen free flame retardant
- Yellow Card UL94 : V0 «All Colors» - 0.8 ; 1.6 & 3mm
- Certification : GWIT 775°C from 0.4mm to 3mm
- Glow wire test GWFI : 960°C / 5 s.
- LOI : 39%
- CTI : 600 V
- Ball Test > 125°C
- Available in different colors
- Fire Resistance
- Halogen and antimony free
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
Properties
- Flame Rating
- Mechanical Properties
Value Units Test Method / Conditions Charpy Notched Impact Strength (cond) 8 kJ/m2 ISO 179-1/1eA Hardness (Cond) 76 Shore D ISO 868 Charpy Notched Impact Strength (dam) 3 kJ/m2 ISO 179-1/1eA Hardness (Dam) 85 Shore D ISO 868 Charpy Unnotched Impact Strength (cond) NB kJ/m2 ISO 179-1/1eU Charpy Unnotched Impact Strength (dam) 40 kJ/m2 ISO 179-1/1eU Elongation at Break (cond) 150 % ISO 527-2/1A Elongation at Break (dam) 5 % ISO 527-2/1A Flexural Modulus (cond) 1100 MPa ISO 178 Flexural Modulus (dam) 3600 MPa ISO 178 Izod Notched Impact Strength (cond) 7 kJ/m2 ISO 180/1A Izod Notched Impact Strength (dam) 2.5 kJ/m2 ISO 180/1A Stress at Break (cond) 40 MPa ISO 527-2/1A Stress at Break (dam) 75 MPa ISO 527-2/1A Stress at Yield Point (cond) 40 MPa ISO 527-2/1A Stress at Yield Point (dam) 75 MPa ISO 527-2/1A - Thermal Properties
Value Units Test Method / Conditions Heat Deflection Temperature 100 °C ISO 75-2/Af Melting Point 220 °C ISO 11357-3 - Electrical Properties
Value Units Test Method / Conditions CTI min. 600 V CEI 60112 - Physico-Chemical Properties
Value Units Test Method / Conditions Density 1.15 g/cm3 ISO 1183-1 Water Absorption (at 24H / 23°C) 0.81 % ISO 62 Water Absorption (at 30Min / 100°C) 0.98 °C ISO 62 - Fire Resistance
Value Units Test Method / Conditions Incandescent Glow Wire Flammability Test (2mm) 960 °C CEI 60695-2-12 Vertical Burning (at 1.6mm) V0 - Test 50W Ul94 Limit Oxygen Index 39 % ISO 4589-2
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Note
- The values indicated above have been realized with standard specimens in room temperature, except if particular conditions:
- dam: specimens 48h after molding
- cond: specimens conditioned according to ISO 291 et ISO 1110. These datas must be considered as indicative values, but in no case as minimum values. Moreover, the design of the mold/die, the processing conditions and the color may have an impact on the properties. The information given herein is the outcome of our research and experience. It is given in all good faith but can neither be interpreted as a warranty given by us nor incur our liability especially in the event of infringement of third party rights.