- Accepta® 2827 is effective over a wide range of pH and can be used in isolation or alternately with other non-oxidizing or oxidizing biocides.
- Highly effective non-oxidizing biocide
- Non-ionic
- Versatile multi-use product
- Accepta® 2827/BC-ITA is effective over a wide range of pH and can be used in isolation or alternately withother non-oxidizing or oxidizing biocides.
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Dosage Rates & Applications
Accepta® 2827/BC-ITA should be dosed periodically at a rate of 100 - 200ppm of the total system volume. In a badly fouled system, an initial shock dose of up to 500ppm may be required. Accepta® 2827/BC-ITA is effective over a wide range of pH and can be used in isolation or alternately with other non-oxidizing or oxidizing biocides.
For chilled water and LTHW systems:
- In order to control potentially problematic microbial contamination it is recommended for chilled water and LTHW applications that the system is dosed initially with Accepta® 2827/BC-ITA at the rate of 200 – 500ml /1000 liters of system volume and that is repeated once every 3 months.
- The microbial activity (TVC) in the system can be monitored using microbial dipslides.
- Good control is indicated by a general bacteria level (TVC) of no more than 103 cfu/ml.
- If pseudomonas or other specific testing is required then contact our laboratory and we will be pleased to help you.
For open evaporative cooling systems:
- In order to prevent the development of resistant microbial strainsAccepta® 2827/BC-ITA should normallybe used in conjunction with another biocide such as Accepta 2301 and the two biocides should be dosed alternately.
- A typical dosing regime would be to dose the system with 200ml of Accepta 2827 / 1000 liters of system volume as a shot dose and then dose the system with a shot dose of the second biocide at the next scheduled dosage before reverting to Accepta® 2827 for the third dosage etc.
- The required frequency of biocide dosage will depend on the retention time of the cooling system and tendency of the system to become contaminated with nutrients that will encourage microbial growth.
- A typical biocide dosing frequency for systems with a long retention time would be once / week but for systems which change their water more frequently and have a short retention time then the frequency of dosages will need to be increased (typically twice per week).
- The general microbial activity (TVC) in the system can be monitored using microbial dipslides. Good control is indicated by a general bacteria level (TVC) of less than 104 cfu/ml. It is recommended that a dipslide test is taken weekly and the system is tested specifically for legionella bacteria at least once per quarter (contact our laboratory).
Properties
- Physical Form
- Appearance
- Pale green coloured liquid
- Odor
- Mild
- Typical Properties
Value Units Test Method / Conditions Density 1.02 - - pH 3.5 - 4.5 - - Specific Gravity 1.00 - 1.02 - - Boiling Point 100.0 °C -
Packaging & Availability
- Packaging
- Weight: 25Kg Drums/Kegs
- Dimensions: 30 × 23 × 47 cm