Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Product Type
- Technologies
Features & Benefits
- Ready-to-Use Product Features
- Product Highlights
- Two-part, translucent, thixotropic, high tear strength silicone systems
- MED1-4213 and MED3-4213 cure at room temperature and all three cure rapidly with the application of heat in an oven, or by a heat gun or lamp
- Many bonding applications do not require the use of a silicone primer for suitable adhesion
- Tin-free, does not require atmospheric moisture to cure
- No curing byproducts such as acetic acid or methyl alcohol
Applications & Uses
- Applications
- Application Area
- Compatible Substrates & Surfaces
- Plastics & Elastomers End Uses
- Applications
- Consistency allows products to be supplied in easy-touse, airless side-by-side kits that eliminate mixing and deairing difficulties
- MED1-4213 has a work time of ~15 minutes, MED2-4213 has a minimum work time of 15 hours, and MED3-4213 has a minimum work time of 60 minutes
- MED1-4213 & MED3-4213 cure in less than 24 hours at room temperature
Properties
- Appearance
- Translucent
- Typical Properties
- Cured Properties
Value | Units | Test Method / Conditions | |
Mix Rat io | 0.042361111 | - | - |
Rheology | Thixotropic / non-slump | - | - |
Work Time | 15.0 | hours | - |
Durometer Type A | 15.0 | - | - |
Elongat ion | 800.0 | % | - |
Specific Gravity | 1.12 | - | - |
Tear | 130 (22.93 ) | ppi (kN/m) | - |
Tensile | 1,000 (6.9 ) | psi (MPa) | - |
Viscosity | 80,000 (80,000 ) | cP (Mpa*s) | - |
Value | Units | Test Method / Conditions | |
Cure Type | Heat Cure | - | - |
Cure Type | Heat Cure | / RTV | - |
Cure at 150 °C | 15.0 | minutes | - |
Cure System | Platinum | - | - |
Packaging & Availability
- Country Availability
- Regional Availability