Under certain conditions the increased thermal conductivity must be considered.
Value | Units | Test Method / Conditions | |
Tensile Modulus | 12500.0 | MPa | ISO 527 |
Tensile Strength | 180.0 | MPa | ISO 527 |
Tensile Elongation at Break | 2.0 | % | ISO 527 |
Impact Strength (Charpy, at 23°C) | 45.0 | kJ/m² | ISO 179/1eU |
Notched Impact Strength (Charpy, at 23°C) | 5.0 | kJ/m² | ISO 179/1eA |
Value | Units | Test Method / Conditions | |
Density | 1200.0 | kg/m³ | ISO 1183 |
Global Warming Potential (GWP) | 5.78 | kg CO₂ eq. | ISO 14040, 14044 |
Value | Units | Test Method / Conditions | |
HDT / A (1.8 MPa) | 252.0 | °C | ISO 75-1/-2 |
DSC (Melt Point) | 260.0 | °C | ISO 11357-1/-3 |
Value | Units | Test Method / Conditions | |
Moisture Content | max. 0.12 | % | - |
Value | Units | Test Method / Conditions | |
Surface Resistance | max. 2500 | Ohm | IEC 62631-3-2 |
Specific Volume Resistance | 29.0 | Ohm*m | IEC 62631-3-1 |
Value | Units | Test Method / Conditions | |
Melt Temperature | 280 - 300 | °C | - |
Mould Temperature | 80 - 120 | °C | - |
Value | Units | Test Method / Conditions | |
Melt Index (MVR) | 15.0 | cm³/10min | ISO 1133 |
MVR Temperature | 300.0 | °C | - |
MVR Load | 1.2 | kg | - |
Molding Shrinkage (parallel) | 0.2 | % | ISO 294-4, 2577 |
Molding Shrinkage (normal) | 0.8 | % | ISO 294-4, 2577 |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Pre-Drying Conditions
- 80°C in an air circulating dryer for 2-8h
- Dependant on moisture content
Storage & Handling
- Storage Conditions
Store in dry, protected from light.