Value | Units | Test Method / Conditions | |
Tensile Modulus | 3300 / 1000 | MPa | ISO 527-1/-2 |
Tensile Modulus (at 120°C) | 800 / - | MPa | ISO 527-1/-2 |
Tensile Modulus (at 160°C) | 650 / * | MPa | ISO 527-1/-2 |
Tensile Modulus (at 180°C) | 600 / * | MPa | ISO 527-1/-2 |
Tensile Modulus (at 200°C) | 500 / * | MPa | ISO 527-1/-2 |
Yield Stress | 100 / 55 | MPa | ISO 527-1/-2 |
Yield Stress (at 120°C) | 50 / * | MPa | ISO 527-1/-2 |
Yield Stress (at 160°C) | 40 / * | MPa | ISO 527-1/-2 |
Tensile Modulus (at -40°C) | 3300 / - | MPa | ISO 527-1/-2 |
Yield Stress (at 180°C) | 35 / * | MPa | ISO 527-1/-2 |
Tensile Modulus (at 100°C) | 850 / - | MPa | ISO 527-1/-2 |
Yield Stress (at 200°C) | 30 / * | MPa | ISO 527-1/-2 |
Nominal Strain (at Break) | 40 / min. 50 | % | ISO 527-1/-2 |
Nominal Strain (at Break, 120°C) | min. 50 / * | % | ISO 527-1/-2 |
Nominal Strain (at Break, 160°C) | min. 50 / * | % | ISO 527-1/-2 |
Nominal Strain (at Break, 180°C) | min. 50 / * | % | ISO 527-1/-2 |
Yield Stress (at -40°C) | 135 / * | MPa | ISO 527-1/-2 |
Nominal Strain (at Break, 200°C) | min. 50 / * | % | ISO 527-1/-2 |
Flexural Modulus | 3000 / 900 | MPa | ISO 178 |
Yield Stress (at 100°C) | 55 / * | MPa | ISO 527-1/-2 |
Flexural Modulus (at 120°C) | 800 / * | MPa | ISO 178 |
Flexural Modulus (at 160°C) | 600 / * | MPa | ISO 178 |
Flexural Strength | 150 / 50 | MPa | ISO 178 |
Flexural Strength (at 120°C) | 50 / * | MPa | ISO 178 |
Yield Strain | 10 / 20 | % | ISO 527-1/-2 |
Flexural Strength (at 160°C) | 40 / * | MPa | ISO 178 |
Nominal Strain (at Break, -40°C) | 20 / - | % | ISO 527-1/-2 |
Charpy Notched Impact Strength (at 23°C) | 10 / 35 | kJ/m² | ISO 179/1eA |
Nominal Strain (at Break, 100°C) | min. 50 / * | % | ISO 527-1/-2 |
Charpy Notched Impact Strength (at -30°C) | 4 / 4 | kJ/m² | ISO 179/1eA |
Izod Notched Impact Strength (at 23°C) | 10 / 35 | kJ/m² | ISO 180/1A |
Charpy Impact Strength (at 23°C) | N / N | kJ/m² | ISO 179/1eU |
Charpy Impact Strength (at -30°C) | N / N | kJ/m² | ISO 179/1eU |
Izod Notched Impact Strength (-40°C) | 4 / 4 | kJ/m² | ISO 180/1A |
Weldline Strength (at thickness 4/*mm) | 100 / 55 | MPa | ISO 527-1/-2 |
Weldline Strength (at thickness 1/*mm) | 95 / 50 | MPa | ISO 527-1/-2 |
Value | Units | Test Method / Conditions | |
Melting Temperature (at 10°C/min) | 295 / * | °C | ISO 11357-1/-3 |
Coefficient of Linear Thermal Expansion (Parallel) | 0.85 / * | E-4/°C | ISO 11359-1/-2 |
Coefficient of Linear Thermal Expansion (Normal) | 1.1 / * | E-4/°C | ISO 11359-1/-2 |
Burning Behaviour (at 1.5/* mm Nominal Thickness) | UL V-2 / * | class | IEC 60695-11-10 |
Burning Behaviour (at 3/* mm Nominal Thickness) | UL V-2 / * | class | IEC 60695-11-10 |
Glass Transition Temperature (10°C/min) | 75 / * | °C | ISO 11357-1/-2 |
Temperature of Deflection Under Load (at 1.80 MPa) | 190 / * | °C | ISO 75-1/-2 |
Temperature of Deflection Under Load (at 0.45 MPa) | 280 / * | °C | ISO 75-1/-2 |
Vicat Softening Temperature (at 50°C/h 50N) | 290 / * | °C | ISO 306 |
Oxygen Index | 27 / * | % | ISO 4589-1/-2 |
Glow Wire Flammability Index (at 3/- mm Thickness) | 650 / - | °C | IEC 60695-2-12 |
Glow Wire Flammability Index (at 0.75/- mm Thickness) | 750 / - | °C | IEC 60695-2-12 |
Glow Wire Ignition Temperature (at 3/- mm Thickness) | 700 / - | °C | IEC 60695-2-13 |
Glow Wire Ignition Temperature (at 0.75/- mm Thickness) | 725 / - | °C | IEC 60695-2-13 |
Relative Temperature Index (Electrical, at 0.75/* mm) | 150 / * | °C | UL746B |
Relative Temperature Index (Electrical, at 3/* mm) | 150 / * | °C | UL746B |
Relative Temperature Index (With Impact, at 0.75/* mm) | 115 / * | °C | UL746B |
Relative Temperature Index (With Impact, at 3/* mm) | 115 / * | °C | UL746B |
Relative Temperature Index (Without Impact, at 0.75/* mm) | 120 / * | °C | UL746B |
Relative Temperature Index (Without Impact, at 3/* mm) | 130 / * | °C | UL746B |
Thermal Index (2500 hrs) | 163 / * | °C | IEC 60216/ISO 527-1/-2 |
Thermal Index (5000 hrs) | 152 / * | °C | IEC 60216/ISO 527-1/-2 |
Thermal Index (10000 hrs) | 141 / * | °C | IEC 60216/ISO 527-1/-2 |
Thermal Index (20000 hrs) | 130 / * | °C | IEC 60216/ISO 527-1/-2 |
Value | Units | Test Method / Conditions | |
Volume Resistivity | 1E13 / 1E7 | Ohm*m | IEC 62631-3-1 |
Electric Strength | 25 / 15 | kV/mm | IEC 60243-1 |
Comparative Tracking Index | 400 / - | V | IEC 60112 |
Relative Permittivity (100Hz) | 3.9 / 22 | - | IEC 62631-2-1 |
Relative Permittivity (1 MHz) | 3.6 / 4.5 | - | IEC 62631-2-1 |
Dissipation Factor (100 Hz) | 70 / 8700 | E-4 | IEC 62631-2-1 |
Dissipation Factor (1 MHz) | 260 / 1200 | E-4 | IEC 62631-2-1 |
Surface Resistivity | - / 1E13 | Ohm | IEC 62631-3-2 |
Value | Units | Test Method / Conditions | |
Viscosity Number | 185 / * | cm³/g | ISO 307, 1157, 1628 |
Value | Units | Test Method / Conditions | |
Density (of Melt) | 990 / * | kg/m³ | - |
Thermal Conductivity of Melt | 0.25 / * | W/(m K) | - |
Specific Heat Capacity Melt | 2670 / * | J/(kg K) | - |
Effective Thermal Diffusivity | 9.21E-8 / * | m²/s | - |
Value | Units | Test Method / Conditions | |
Humidity Absorption | 3.7 / * | % | Sim. to ISO 62 |
Density | 1180 / - | kg/m³ | ISO 1183 |
Water Absorption | 13.5 / * | % | Sim. to ISO 62 |
Water Absorption in Water (at 23°C, after 24h) | 3.8 / * | % | ISO 62 |
Value | Units | Test Method / Conditions | |
Molding Shrinkage (Parallel) | 2 / * | % | Sim. to ISO 294-4 |
Molding Shrinkage (Normal) | 2 / * | % | Sim. to ISO 294-4 |
Spiral Flow Length (1.0 mm, at 800 bar) | 110 / * | mm | - |
Spiral Flow Length (1.0 mm, at 900 bar) | 120 / * | mm | - |
Spiral Flow Length (1.0 mm, at 1000 bar) | 130 / * | mm | - |
Spiral Flow Length (0.5 mm, at 1200 bar) | 60 / * | mm | - |
Spiral Flow Length (0.5 mm, at 1600 bar) | 70 / * | mm | - |
Spiral Flow Length (0.5 mm, at 2000 bar) | 90 / * | mm | - |
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Chemical Resistance Data
Chemical Name Chemical Resistance Acetaldehyde (40% by mass) at 23°C Resistant Acetamide (50% by mass) at 23°C Limited resistant, tests necessary to verify
Acetamide (50% by mass) at >140°C Not resistant Acetic acid (10% by mass) at 100°C Not resistant Acetic acid (10% by mass) at 23°C Limited resistant, tests necessary to verify
Acetic acid (95% by mass) at 23°C Not resistant Acetone at 23°C Resistant Acetophenone at 23°C Resistant Acetyl chloride at 23°C Not resistant Acetylene at 23°C Resistant Acrylic acid at 23°C Not resistant Aliphatic amines at 23°C Resistant Aliphatic hydrocarbons at 23°C Resistant Alkylbenzenes at 23°C Resistant Allyl alcohol at 23°C Limited resistant, tests necessary to verify
Aluminum acetate (saturated) at 23°C Resistant Aluminum chloride (10% by mass) at 23°C Resistant Aluminum hydroxide (saturated) at 23°C Resistant Aluminum salts of mineral acids (saturated) at 23°C Limited resistant, tests necessary to verify
Aluminum trichloride (10% by mass) at 23°C Resistant Amino acids (saturated) at 23°C Resistant Ammonia at 23°C Limited resistant, tests necessary to verify
Ammonium chloride (35% by mass) at 100°C Limited resistant, tests necessary to verify
Ammonium chloride (35% by mass) at 23°C Resistant Ammonium salts of mineral acids (10% by mass) at 23°C Resistant Ammonium salts of mineral acids (10% by mass) at 50°C Limited resistant, tests necessary to verify
Ammonium thiocyanate (saturated) at 23°C Resistant Amyl acetate at 100°C Not resistant Amyl acetate at 23°C Resistant Amyl alcohol at 23°C Resistant Aniline at 23°C Limited resistant, tests necessary to verify
Anodizing liquid (HNO3/H2SO4) at 23°C Limited resistant, tests necessary to verify
Antimony trichoride (saturated) at 23°C Not resistant Aqua Regia (HCl/HNO3) at 23°C Not resistant Aromatic hydrocarbons at 23°C Resistant ASTM 3 at 23°C Limited resistant, tests necessary to verify
Bariumsalts of mineral acids at 23°C Limited resistant, tests necessary to verify
Benzaldehyde at 23°C Limited resistant, tests necessary to verify
Benzene at 23°C Resistant Benzene at 80°C Resistant Benzoic acid (20% by mass) at 23°C Limited resistant, tests necessary to verify
Benzoic acid (saturated) at 23°C Not resistant Benzyl alcohol at 23°C Limited resistant, tests necessary to verify
Beverages at 23°C Resistant Bleaching agent (NaOCl) at 23°C Not resistant Boric acid (10% by mass) at 23°C Limited resistant, tests necessary to verify
Boron trifluoride at 23°C Not resistant Brake fluids (DOT 3/4) at 23°C Resistant Bromine water (saturated) at 23°C Not resistant Bromochlorodifluoromethane at 23°C Resistant Bromotrifluoromethane at 23°C Resistant Butadiene at 23°C Resistant Butane at 23°C Resistant Butanediols at 23°C Resistant Butanediols at >140°C Limited resistant, tests necessary to verify
Butanols at 23°C Resistant Butene glycol at 23°C Resistant Butene glycol at >160°C Limited resistant, tests necessary to verify
Butene-1 at 23°C Resistant Butter at 23°C Limited resistant, tests necessary to verify
Butyl acetate at 23°C Resistant Butyl acrylate at 23°C Resistant Butyl glycolate at 23°C Resistant Butyl phthalate at 23°C Resistant Butyric acid (20% by mass) at 23°C Limited resistant, tests necessary to verify
Butyrolactone at 23°C Resistant Butyrolactone at >90°C Limited resistant, tests necessary to verify
Calcium chloride (10% by mass) at 100°C Limited resistant, tests necessary to verify
Calcium chloride (10% by mass) at 23°C Resistant Calcium chloride (alcoholic) (20% by mass) at 23°C Limited resistant, tests necessary to verify
Calcium chloride (saturated) at 100°C Not resistant Calcium chloride (saturated) at 23°C Resistant Calcium chloride (saturated) at 60°C Limited resistant, tests necessary to verify
Calcium hydroxide (saturated) at 23°C Resistant Calcium hypochloride (saturated) at 23°C Not resistant Camphor (alcoholic) (50% by mass) at 23°C Resistant Caprolactam (50% by mass) at 23°C Resistant Caprolactam (50% by mass) at >150°C Limited resistant, tests necessary to verify
Carbon disulfide at 23°C Resistant Carbon disulfide at 60°C Not resistant Carbon tetrachloride at 23°C Resistant Casein at 23°C Resistant Chloral hydrate at 23°C Not resistant Chloramines (10% by mass) at 23°C Not resistant Chlorinated biphenyls at 80°C Limited resistant, tests necessary to verify
Chlorine water at 23°C Not resistant Chloroacetic acid (10% by mass) at 23°C Not resistant Chlorobenzene at 23°C Resistant Chlorobenzene at 50°C Resistant Chlorobromomethane at 23°C Limited resistant, tests necessary to verify
Chlorodifluoroethane at 23°C Resistant Chlorodifluoromethane at 23°C Resistant Chlorofluoroethylene at 23°C Resistant Chloroform at 23°C Not resistant Chlorosulfonic acid (10% by mass) at 23°C Not resistant Chromic acid (1% by mass) at 23°C Limited resistant, tests necessary to verify
Chromic acid (10% by mass) at 23°C Not resistant Chromyl chloride at 23°C Not resistant cis-2-butene at 23°C Resistant Citric acid (10% by mass) at 23°C Limited resistant, tests necessary to verify
Cobalt salt (20% by mass) at 23°C Limited resistant, tests necessary to verify
Copper sulfate (10% by mass) at 23°C Resistant Copper(II) salt (10% by mass) at 23°C Limited resistant, tests necessary to verify
Cresols at 23°C Not resistant Cycloalcohols (incl their esters) at 23°C Resistant Cycloalkanes at 23°C Resistant Cycloalkanones at 23°C Resistant Decalin at 23°C Resistant Developer (photografic) at 23°C Resistant Dibutyl phthalate at 23°C Resistant Dibutyl phthalate at 60°C Resistant Dichlorobenzene at 23°C Resistant Dichloroethane at 23°C Resistant Dichloroethylene at 23°C Resistant Dichlorofluoromethane at 23°C Resistant Dichlorotetrafluoroethane at 23°C Resistant Diethyl ether at 23°C Resistant Diethylene glycol at 23°C Resistant Diethylene glycol at >140°C Not resistant Difluoromethane at 23°C Resistant Dimethyl acetamide at 23°C Resistant Dimethyl acetamide at >150°C Not resistant Dimethyl ether at 23°C Resistant Dimethylamine at 23°C Resistant Dimethylformamide at 23°C Resistant Dimethylformamide at 90°C Limited resistant, tests necessary to verify
Dimethylsilane at 23°C Resistant Dimethylsulfoxide at 125°C Not resistant Dimethylsulfoxide at 23°C Resistant Dioctyl phtalate at 23°C Resistant Dioxan at 23°C Resistant Dioxan at 60°C Resistant Diphenyl ether at 80°C Resistant Dipropyl ether at 23°C Resistant Edible fats waxes and oils at 100°C Limited resistant, tests necessary to verify
Electroplating bath (acidic) at 23°C Not resistant Electroplating bath (alkali) at 23°C Resistant Ethane at 23°C Resistant Ethanol at 23°C Resistant Ethyl Acetate at 23°C Resistant Ethyl chloride at 23°C Resistant Ethylene at 23°C Resistant Ethylene carbonate at 100°C Not resistant Ethylene carbonate at 50°C Resistant Ethylene chlorohydrin at 23°C Limited resistant, tests necessary to verify
Ethylene glycol at 100°C Not resistant Ethylene glycol at 23°C Resistant Ethylene oxide at 23°C Resistant Ethylene oxide at >80°C Not resistant Ethylenediamine at 23°C Resistant Fatty acids at 23°C Resistant Fatty alcohols at 23°C Resistant Fixer (photografic) at 23°C Resistant Fluorinated hydrocarbons at 70°C Resistant Fluorine at 23°C Not resistant Formaldehyde (30% by mass) at 23°C Resistant Formamide at 23°C Resistant Formamide at >150°C Not resistant Formic acid (10% by mass) at 23°C Not resistant Formic acid (10% by mass) at 50°C Not resistant Fruit juices at 23°C Limited resistant, tests necessary to verify
Fuel; Diesel at 85°C Resistant Fuel; FAM 1A at 23°C Resistant Fuel; FAM 2A at 23°C Limited resistant, tests necessary to verify
Fuel; Gasoline at 85°C Limited resistant, tests necessary to verify
Fuel; LPG at 23°C Limited resistant, tests necessary to verify
Furfural at 23°C Limited resistant, tests necessary to verify
Furfuryl alcohol at 23°C Limited resistant, tests necessary to verify
Glucose at 23°C Limited resistant, tests necessary to verify
Glycerol at 170°C Limited resistant, tests necessary to verify
Glycerol at 23°C Limited resistant, tests necessary to verify
Glycolic acid (30% by mass) at 23°C Limited resistant, tests necessary to verify
Glycols at 23°C Limited resistant, tests necessary to verify
Grease (based on ester oils) at <100°C Limited resistant, tests necessary to verify
Grease (based on metal soaps) at <100°C Limited resistant, tests necessary to verify
Grease (based on polyphenylester) at <100°C Limited resistant, tests necessary to verify
Hardening oils at 23°C Resistant Heating oils at 23°C Resistant Heptane at 23°C Resistant Hexachlorobenzene at 80°C Resistant Hexachloroethane at 23°C Resistant Hexafluoroisopropanol at 23°C Not resistant Hexane at 23°C Resistant Hydraulic fluids at 100°C Resistant Hydrobromic acid (10% by mass) at 23°C Not resistant Hydrochloric acid (10% by mass) at 23°C Not resistant Hydrochloric acid (20% by mass) at 23°C Not resistant Hydrochloric acid (conc.% by mass) at 23°C Not resistant Hydrofluoric acid (40% by mass) at 23°C Not resistant Hydrofluoric acid (5% by mass) at 23°C Not resistant Hydrogen at 23°C Resistant Hydrogen peroxide (0.5% by mass) at 23°C Resistant Hydrogen peroxide (3% by mass) at 23°C Not resistant Hydrogen peroxide (30% by mass) at 23°C Not resistant Hydrogen sulfide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Hydroiodic acid at 23°C Not resistant Hydroquinone (5% by mass) at 23°C Not resistant Impregnating oils at 23°C Resistant Ink at 23°C Resistant Iodine (alcoholic) at 23°C Not resistant Iron(III)chloride (acidic) (10% by mass) at 23°C Not resistant Iron(III)chloride (neutral) (10% by mass) at 23°C Limited resistant, tests necessary to verify
Iron(III)chloride (saturated) at 23°C Not resistant Iron(III)thiocyanate (10% by mass) at 23°C Limited resistant, tests necessary to verify
Isocyanates (aromatic) at 23°C Resistant Isooctane at 80°C Resistant Isopropanol at 23°C Resistant Isopropanol at 60°C Resistant Ketones (aliphatic) at 23°C Resistant Lactic acid at 10°C Resistant Lactic acid at 90°C Not resistant Lead acetate (10% by mass) at 23°C Resistant Linseed oil at 23°C Resistant Lithium bromide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Lithium chloride (20% by mass) at 23°C Not resistant Lithium hydroxide (10% by mass) at 23°C Resistant Lithium hydroxide (10% by mass) at 80°C Not resistant Lubricating oil (gear) at <130°C Resistant Lubricating oil (hydraulics) at <130°C Resistant Lubricating oil (transformers) at <130°C Resistant Magnesium hydroxide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Magnesium salts (10% by mass) at 23°C Resistant Maleic acid (25% by mass) at 23°C Limited resistant, tests necessary to verify
Maleic acid (saturated) at 23°C Resistant Manganese salts (10% by mass) at 23°C Resistant Mercury at 23°C Resistant Mercury(II)chloride (saturated) at 23°C Not resistant Methane at 23°C Resistant Methanol at 23°C Limited resistant, tests necessary to verify
Methyl acetate at 23°C Resistant Methyl chloride at 23°C Resistant Methyl ethyl ketone at 23°C Resistant Methyl formate at 23°C Resistant Methyl glycol at 23°C Resistant Methylamine at 23°C Resistant Methylaniline at 23°C Resistant Methylbromide at 23°C Resistant Methylene chloride at 23°C Limited resistant, tests necessary to verify
Methylpyrrolidone at 23°C Resistant Milk at 23°C Limited resistant, tests necessary to verify
n-Butyl ether at 23°C Resistant n-Butyl glycol at 23°C Resistant Naphtha at 23°C Resistant Naphthalene at 23°C Resistant Naphthalenesulfonic acids at 23°C Not resistant Naphthenic acids at 23°C Resistant Naphthols at 23°C Not resistant Nickel nitrate (10% by mass) at 23°C Limited resistant, tests necessary to verify
Nickel salts (10% by mass) at 23°C Resistant Nitric acid (2% by mass) at 23°C Not resistant Nitric acid (conc.% by mass) at 23°C Not resistant Nitrobenzene at 23°C Limited resistant, tests necessary to verify
Nitrobenzene at >100°C Not resistant Nitrocellulose lacquers (alcoholic) at 23°C Limited resistant, tests necessary to verify
Nitrocellulose lacquers (non-alcoholic) at 23°C Resistant Nitrogen oxides at 23°C Limited resistant, tests necessary to verify
Nitromethane at 23°C Limited resistant, tests necessary to verify
Nitropropane at 23°C Limited resistant, tests necessary to verify
Nitrotoluene at 23°C Limited resistant, tests necessary to verify
Nitrotoluene at >100°C Not resistant Nitrous fumes at 23°C Limited resistant, tests necessary to verify
Nitrous oxide at 23°C Resistant Octane at 23°C Resistant Octene at 23°C Resistant Oil (Burmah TAF 21) at 23°C Resistant Oil (Castrol TAF) at 23°C Resistant Oil (Shell 10W40) at 23°C Resistant Oil (Shell Dexron ATF) at 23°C Resistant Oil (Shell Spirax EP90) at 23°C Limited resistant, tests necessary to verify
Oil (transformers, switchgear) at 50°C Resistant Oils (vegatable, mineral, ethereal) at 23°C Resistant Oleic acid at 23°C Resistant Oleum (H2SO4+SO3) at 23°C Not resistant Oxalic acid (10% by mass) at 23°C Limited resistant, tests necessary to verify
Oxalic acid (10% by mass) at 80°C Not resistant Ozone at 23°C Not resistant Paint solvents at 23°C Resistant Palmatic acid at 80°C Resistant Paraffin at 23°C Resistant Pentasin CHF 11 (S) at 23°C Resistant Pentasin CHF 7.1 at 23°C Limited resistant, tests necessary to verify
Peracetic acid at 23°C Not resistant Petroleum at 23°C Resistant Petroleum ether and solvents at 80°C Resistant Phenol (alc. sol.) (70% by mass) at 23°C Limited resistant, tests necessary to verify
Phenol (conc.% by mass) at 23°C Not resistant Phenol at >40°C Not resistant Phenyl ether at 23°C Not resistant Phenyl ethyl alcohol at 23°C Limited resistant, tests necessary to verify
Phenyl ethyl alcohol at >160°C Not resistant Phosphate sol. (neutral, alkaline) (10% by mass) at 23°C Resistant Phosphine at 23°C Resistant Phosphoric acid (10% by mass) at 23°C Not resistant Phosphoric acid (conc.% by mass) at 23°C Not resistant Phthalic acid (saturated) at 23°C Limited resistant, tests necessary to verify
Polyols at 23°C Resistant Potassium bromide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Potassium chloride (10% by mass) at 23°C Resistant Potassium chloride (10% by mass) at 70°C Resistant Potassium dichromate (5% by mass) at 23°C Limited resistant, tests necessary to verify
Potassium hydroxide (50% by mass) at 23°C Limited resistant, tests necessary to verify
Potassium nitrate (10% by mass) at 23°C Resistant Potassium permanganate (1% by mass) at 23°C Not resistant Potassium thiocyanate (saturated) at 23°C Not resistant Propane at 23°C Resistant Propanol at 23°C Resistant Propanol at >100°C Not resistant Propene at 23°C Resistant Propionic acid (5% by mass) at 23°C Resistant Propionic acid (50% by mass) at 23°C Not resistant Pyridine at 23°C Resistant Pyridine at 80°C Limited resistant, tests necessary to verify
Pyrrolidone at 23°C Resistant Pyruvic acid (10% by mass) at 23°C Limited resistant, tests necessary to verify
Rainwater (acidic) at 23°C Resistant Refrigerator oil at 23°C Resistant Resorcinol (alcoholic) (50% by mass) at 23°C Not resistant Road salts at 23°C Resistant SAE 80 at 23°C Resistant Salicylic acid (saturated) at 23°C Resistant Seawater at 23°C Resistant Silane at 23°C Resistant Silicone oils at <80°C Resistant Silicone oils at >100°C Limited resistant, tests necessary to verify
Silver nitrate (10% by mass) at 23°C Resistant Soap solution (10% by mass) at 80°C Limited resistant, tests necessary to verify
Sodium bromide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Sodium carbonate (10% by mass) at 23°C Resistant Sodium chlorate (10% by mass) at 23°C Resistant Sodium chloride (10% by mass) at 23°C Resistant Sodium chlorite (10% by mass) at 23°C Limited resistant, tests necessary to verify
Sodium cyanide (10% by mass) at 23°C Resistant Sodium dichromate (10% by mass) at 23°C Resistant Sodium dodecylbenzenesulfonate at 23°C Resistant Sodium hydrogen carbonate (10% by mass) at 23°C Resistant Sodium hydrogen sulfate (10% by mass) at 23°C Resistant Sodium hydrogen sulfite (10% by mass) at 23°C Resistant Sodium hydroxide (10% by mass) at 23°C Limited resistant, tests necessary to verify
Sodium hydroxide (10% by mass) at 80°C Not resistant Sodium hydroxide (50% by mass) at 23°C Not resistant Sodium hypochlorite (10% by mass) at 23°C Not resistant Sodium hypophosphite (10% by mass) at 23°C Resistant Sodium lauryl sulfate (30% by mass) at 23°C Resistant Sodium lignosulfonate at 23°C Resistant Sodium nitrilotriacetate (10% by mass) at 23°C Resistant Sodium oleate at 23°C Resistant Sodium pentachlorophenolate at 23°C Resistant Sodium pyrosulfite (10% by mass) at 23°C Resistant Sodium salts (nitrate, sulfate) (10% by mass) at 23°C Resistant Soldering fluid at 23°C Not resistant Steam at 23°C Limited resistant, tests necessary to verify
Stearate at 23°C Resistant Stearic acid at 23°C Resistant Styrene at 80°C Resistant Sulfonates (10% by mass) at 23°C Resistant Sulfur at 23°C Resistant Sulfur dioxide (dry) at 23°C Resistant Sulfur dioxide (moist) at 23°C Limited resistant, tests necessary to verify
Sulfur hexafluoride at 23°C Resistant Sulfuric acid (2% by mass) at 23°C Not resistant Sulfuric acid (conc.% by mass) at 23°C Not resistant Sulfurous acid (saturated) at 23°C Limited resistant, tests necessary to verify
Tartaric acid (10% by mass) at 23°C Resistant Tartaric acid (50% by mass) at 23°C Limited resistant, tests necessary to verify
Tetrachloroethylene at 23°C Limited resistant, tests necessary to verify
Tetrachloroethylene at 80°C Not resistant Tetrachloromethane at 23°C Resistant Tetrafluoromethane at 23°C Resistant Tetrafluoropropanol at 23°C Not resistant Tetrahydrofuran at 23°C Resistant Tetralin at 23°C Resistant Tetramethylenesulfone at 23°C Resistant Toluene at 100°C Resistant Toluene at 23°C Resistant Transformer oil at 23°C Resistant Trichloroacetic acid (50% by mass) at 23°C Not resistant Trichloroacetic acid ethyl ester at 23°C Limited resistant, tests necessary to verify
Trichloroethane at 45°C Resistant Trichloroethanol at 23°C Not resistant Trichloroethylene at 23°C Limited resistant, tests necessary to verify
Trichloroethylene at >40°C Not resistant Trichlorotrifluoroethane at 23°C Resistant Trietanolamine at 23°C Resistant Trifluoroethanol at 23°C Not resistant Trimethylamine at 23°C Resistant Turpentine oil at 23°C Resistant Turpentine substitute at 23°C Resistant Uranium fluoride at 23°C Not resistant Urea (20% by mass) at 23°C Resistant Uric acid (20% by mass) at 23°C Resistant Urine at 23°C Resistant Vaseline (acid free) at 23°C Resistant Vinyl bromide at 23°C Resistant Vinyl chloride at 23°C Resistant Vinyl fluoride at 23°C Resistant < - Viscosity Shear Rate
- Shearstress Shear Rate
- Dynamic Shear Modulus (G) Temperature (Dry)
- Stress Strain (Dry)
- Stress Strain Conditioned
- Secant Modulus Strain (Dry)
- Secant Modulus Strain Conditioned
- Stress Strain (Isochronous) 23°C (Dry)
- Stress Strain (Isochronous) 100°C (Dry)
- Stress Strain (Isochronous) 140°C (Dry)
- Stress Strain (Isochronous) 160°C (Dry)
- Tensile Fatigue 8Hz, T, R=0.1 (Dry)
Storage & Handling
- Storage Information
In order to prevent moisture pick up and contamination, supplied packaging should be kept closed and undamaged. For the same reason, partial bags should be sealed before re-storage. Allow the material that has been stored elsewhere to adapt to the temperature in the processing room while keeping the bag closed.