company tower banner
Dampney Company, Inc. Company Logo
Endcor® 560C is a multipurpose alkyd primer used for new construction and maintenance applications. It can be applied over a wide range of coated and uncoated surfaces without lifting or softening the existing coating. An economical rust inhibitive primer for exterior and interior steel surfaces subjected to industrial and marine environments. It exhibits strong intercoat adhesion, serving as an outstanding tie coat between previously applied adherent paint and chemically resistant topcoat systems containing active solvents.

Product Type: Primer

Application Area: Bridges, Marine Applications, Tanks

Compatible Substrates & Surfaces: Coated Surfaces, Metal, Steel

Features: Corrosion Resistant, Cost Effective, Excellent Intercoat Adhesion, Excellent Substrate Adhesion

Application Method: Brush, Roller, Spray

Chemical Family: Alkyds

Technical Data Sheet
  • TypeDocument Name
View All Documents

Knowde Enhanced TDS

Identification & Functionality

Chemical Family
Product Type

Features & Benefits

Features
  • Outstanding adhesion to all substrates
  • Excellent intercoat adhesion
  • Compatible with numerous topcoat types
  • Bonds well to old adherent paint films
  • Prevents corrosion and undercutting
  • Resists lifting by strong solvents
  • High film build

Applications & Uses

Application Method
Compatible Substrates & Surfaces
Uses
  • Shop primer for structural steel
  • Structural steel-bridges, industrial plants
  • Power plant structures, smoke stacks
  • Refinery and chemical process plant structures
  • Water and sewage works structures
  • Paper mill structures
  • Storage tank exteriors-water, petroleum, etc.
Not Recommended
  • Immersion Service
  • Chemical or aromatic solvent exposure
  • Temperatures over 200°F (93°C)
  • Not to be used as a finish coating
Surface Preparation

For Shop Priming New Steel, or Field Painting New Structures surfaces must be clean, dry and free from oil, grease, dirt, welding flux, mill scale, rust, oxides, corrosion products, loose paint, or any foreign matter detrimental to the adhesion of this primer. Abrasive blast all surfaces per SSPC-SP-6 “Commercial Blast Cleaning”. If abrasive blasting is not permitted removeall loose rust, corrosion products, paint and other foreign matter per SSPC-SP-11,”Power tool cleaning” using a Desco air operated tool with a “Roto Peen” flap assembly attached.

For Maintenance Painting

Remove oil and grease by solvent cleaning. Pressure wash to decontaminate all surfaces. Remove loose, cracked, brittle or non-adherent paints, spot clean rust spots by power tooling per SSPC-SP-11. Feather out exposed edges where remaining paint is sound.

Aluminum or Galvanized Surfaces

Age and degree of contamination and/or deterioration of surfaces will determine method of surface preparation. Brush blasting per SSPC-SP-7, or treating surfaces to be coated with Endcor 400 Wash Primer or with Endcor 450 Prep Wash.

Mixing

Redisperse any settled-out pigments by stirring with a paint paddle, followed by through mixing to a uniform consistency with an explosion proof power mixer.

Drying Time

Endcor 560C is ready to recoat in 6 - 8 hours.

Cleanup

Flush equipment, hoses, clean spray gun and spray tips after use with Dampney 100 thinner.

Application

Apply by conventional or airless spray, brush or roller. Apply to a 2-3 mil dry film thickness (4-6 mils wet). If exceptionally rough surfaces are encountered, apply a second coat to a dry film thickness of 6 - 8 mils wet.

Application Guidelines

Primer is formulated for application by brush, roller, airless or conventional spray. The following equipment or equivalent, may be used

  • Brush : Use pure bristle brushes only. Do not over brush, use full even strokes.
  • Roller : Use 1/4” to 5/8” nap rollers. Avoid excess rolling.

Note : Extra coats of primer may be required for uniform film thickness when applied via brush or roller.

Conventional Spray

Spray gun Binks 2001
Air hose 5/16" (I.D.)
*Fluid hose 3/8" (I.D.)
Air cap & Fluid nozzle 63Bx63PB
Pot pressure 10-15lbs.
Atomizing pressure 35-40lbs.

*Smaller diameter hoses or hose lengths greater than 25 feet may make it necessary to increase pressures.

Airless Spray Equipment

Pump

Graco Bulldog 30:1

Gun

Graco 205-591, 208-663

Fluid tips*

Graco 163-615, 162-619

Fluid hose 3/8” to 1/2’’ ID
Air pressure to pump 100 psi
Pump operating pressure 80-90psi

* Use Reverse-A-Clean tips for easy clean out. Note: Pump gasket should be teflon.

Application Temperature

Do not apply primer if surface, material or air temperature is below 50°F (10°C) or if relative humidity is above 80%

Recommended Topcoat Systems

  • Endcor 300 Series Vinyl Coatings
  • Endcor 500 Series Alkyd Coatings
  • Endcor 570 Series Silicone Alkyd Coatings
  • Endcor 600 Series Chlorinated Rubber Coatings
  • Endcor 700 Series Polyamide-cured Epoxy Coatings

Topcoating Procedures

Allow 6-8 hours before application of coatings, containing mild solvents (acrylic, alkyd, chlorinated rubber, oleo-resinous, etc.). Allow 16 hours minimum before application of coatings containing active solvents (epoxy, urethane, vinyl, etc.)

Properties

Color
Typical Properties
ValueUnitsTest Method / Conditions
FinishFlat--
Temperature Resistance (Continuous)65.6°C-
Temperature Resistance (Intermittent)93.3°C-
Solids by volume49.0%-
Dry Film Thickness per Coat2 - 3mils-
Wet Film Thickness per Coat5 - 6mils-
Theoretical Coverage per gallon786 *mil. sq. ft.-
Application Temperature (50% RH)10 - 50°C-
Drying Time (50% RH to Touch at 50°F (10°C))8 - 10Hours
Drying Time (50% RH to Recoat , 50°F (10°C))24Hours
Drying Time (50% RH to Ship , 50°F (10°C))72Hours
Drying Time (50% RH To Touch at 70°F (21°C))6 - 8Hours
Drying Time (50% RH to Recoat , 70°F (21°C))10 - 12Hours
Drying Time (50% RH to Ship At 70°F (21°C))48Hours
Viscosity65 - 70Ku-
Flash Point6.7°C-
Volatile Organic Compounds3.44lbs/gal-
Note

*Actual coverage rate will vary depending upon material losses during mixing and application, and upon type and condition of surface to be coated. Allowance must be made for losses when estimating material requirements.

Safety & Health

Precautionary Information

Warning ! Flammable liquid and vapor. Harmful if inhaled. May affect the brain or nervous system causing dizziness, headache or nausea. Causes, nose, throat and skin irritation.

Caution : Keep away from heat, sparks, arc and flame. Vapors may cause flash fire. Close container after each use. Do not breathe vapors or spray mist. Use only with adequate ventilation during mixing application and curing. Wear a vapor/ particulate respirator, such as NIOSH/MSHA No TC-23C, during and after application and until work areas are exhausted of vapors and mists. Follow respirator manufacturer’s directions for use. Avoid contact with eyes, skin and clothing, Wash thoroughly after handling. Wear rubber gloves, chemical safety goggles and protective clothing. Use skin cream.

In unventilated areas or confined spaces require a constant-flow, air-line respirator, such as NIOSH/ MSHA No. TC-19C. Use explosion-proof lights and electrical equipment. Make certain all electrical equipment is grounded. Wear conductive and nonsparking shoes. Follow safety procedures described in OSHA regulations. Use only nonsparking tools and equipment. Wear conductive and nonsparking foot wear. Make certain all electrical equipment is grounded.

Packaging & Availability

Packaging
  • Weight per gallon
Endcor 560C Series 11.1 lbs
Dampney 100 Thinner 7.2 lbs.
  • Shipping Weights
Endcor 560C Primer 1”s 5's
Dampney 100 12.2 lbs. 61lbs.
Thinner 7.2lbs. 36.0 lbs.

Storage & Handling

Shelf Life
1 Year