Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Industrial Additives Functions
- Technologies
Features & Benefits
- Industrial Additives Features
- Features
- Consistent performance: The product meets a tight chemical specification and provides emulsions with consistently good performance with low and medium reactive aggregates
- Easy to use: The product has relatively low viscosity and dissolves easily in the water phase
Applications & Uses
- Markets
- Applications
- Applicable Processes
- Industrial Additives End Use
- Use Level
- 0.01-1.5%
- Application pH Range
- 1-2.5
- Dosage
Slurry and micro surfacing emulsion 0.8-1.5% pH 1-2.5 hydrochloric acid
Break retarder 0.01-0.05% basis mixture
Properties
- Physical Properties
- Characteristics
- Specifications
- Note
- The product is sold under the tradename Redicote 404 in some countries.
Value | Units | Test Method / Conditions | |
Density (at 10°C (50°F)) | 0.96 (8.00) | g/cc (lbs/U.S. gal) | - |
Density (at 20°C (68°F)) | 0.95 (7.96) | g/cc (lbs/U.S. gal) | - |
Density (at 30°C (86°F)) | 0.95 (7.93) | g/cc (lbs/U.S. gal) | - |
Density (at 40°C (104°F)) | 0.94 (7.89) | g/cc (lbs/U.S. gal) | - |
Viscosity (at 10°C (50°F)) | 1150 | mPa s (cP) | - |
Viscosity (at 20°C (68°F)) | 550 | mPa s (cP) | - |
Viscosity (at 30°C (86°F)) | 250 | mPa s (cP) | - |
Viscosity (at 40°C (104°F)) | 150 | mPa s (cP) | - |
Flash Point | min. 100 | °C |
Value | Units | Test Method / Conditions | |
Pour Point | -7 (19) | °C(°F) | - |
Value | Units | Test Method / Conditions | |
Amine Value | 385 - 415 | mg KOH/g | SMA CL-002 |
Packaging & Availability
- Packaging Type
- Regional Availability
- Packaging Information
- Redicote C-404 is available in bulk shipment, in tight head steel drums of 400 lbs (181 kg) net weight, or in one-way totes (IBCs) of 2000 lbs (907 kg) net weight.
Storage & Handling
- Storage Conditions
- Redicote C-404 may be stored in carbon steel tanks. Bulk storage should be maintained at 10-35°C (50-95°F). Avoid extended heating above 65°C (150+F). Protect against exposure to moisture.
- Redicote C-404 contains amines and may cause severe irritation or burns to skin and eyes. Protective goggles and gloves must be worn when handling this product.