Knowde Enhanced TDS
Identification & Functionality
- Chemical Family
- Fillers Included
- Polymer Name
- Plastics & Elastomers Functions
- Technologies
Features & Benefits
- Labeling Claims
- Materials Features
Applications & Uses
- Markets
- Applications
- Plastics & Elastomers End Uses
- Plastics & Elastomers Processing Methods
- Resins and Compounds for Water Management Applications
SABIC’S specialty resins and compounds offer the water management industry design flexibility to produce products with longer lives and higher quality. Our materials are excellent candidates to replace metal and can provide weight reduction, corrosion resistance, high strength and stiffness or inherent lubricity depending on the application’s requirements.
- Thermal resistance
- Structural mechanical performance
In addition to mechanical requirements, applications for the water management industry need certification for potable water compliance according to national standards. SABIC has developed a dedicated potable water certified portfolio to help our customers accelerate their application development time to market.
SABIC Offerings Certified for Water Management Applications:
For applications that do not require potable water certification, SABIC’s Specialties portfolio includes a wide range of specialized thermoplastic compounds based on different base resins and fillers.
Properties
- Flame Rating
- Mechanical Properties
- Physical Properties
- Thermal Properties
- Electrical Properties
- Impact Properties
- Injection Molding
- Flame Characteristics
- Note
- ᵍ Measurements made from Laboratory test Coupon. Actual shrinkage may vary outside of range due to differences in processing conditions, equipment, part geometry and tool design. It is recommended that mold shrinkage studies be performed with surrogate or legacy tooling prior to cutting tools for new molded article.
- ᵖ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card.
- ⁷ Injection Molding parameters are only mentioned as general guidelines. These may not apply or may need adjustment in specific situations such as low shot sizes, large part molding, thin wall molding and gas-assist molding.
- ¹¹ The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
- ¹⁷ UL ratings shown on the technical datasheet might not cover the full range of thicknesses and colors. For details, please see the UL Yellow Card. The information stated on Technical Datasheets should be used as indicative only for material selection purposes and not be utilized as specification or used for part or tool design.
Value | Units | Test Method / Conditions | |
Tensile Stress (Break, 5 mm/min) ¹¹ | 160 | MPa | ISO 527 |
Tensile Stress (Break, 5 mm/min) ¹¹ | 182 | MPa | ISO 527 |
Tensile Stress (Break, Type I, 5 mm/min) ¹¹ | 178 | MPa | ASTM D638 |
Tensile Stress (Break) ¹¹ | 160 | MPa | ISO 527 |
Tensile Stress (Break) ¹¹ | 178 | MPa | ASTM D638 |
Tensile Strain (Break, 5 mm/min) ¹¹ | 1.7 | % | ISO 527 |
Tensile Strain (Break, 5 mm/min) ¹¹ | 1.2 | % | ISO 527 |
Tensile Strain (Break, Type I, 5 mm/min) ¹¹ | 1.7 | % | ASTM D638 |
Tensile Strain (Break) ¹¹ | 1.7 | % | ASTM D638 |
Tensile Strain (Break) ¹¹ | 1.2 | % | ISO 527 |
Flexural Stress (Break, 2 mm/min) ¹¹ | 271 | MPa | ISO 178 |
Flexural Stress (Yield, 1.3 mm/min, 50 mm span) ¹¹ | 248 | MPa | ASTM D790 |
Flexural Stress ¹¹ | 248 | MPa | ASTM D790 |
Flexural Stress ¹¹ | 190 | MPa | ISO 178 |
Flexural Modulus (at 1.3 mm/min, 50 mm span) ¹¹ | 14260 | MPa | ASTM D790 |
Flexural Modulus (at 2 mm/min) ¹¹ | 14000 | MPa | ISO 178 |
Flexural Modulus (at 2 mm/min) ¹¹ | 13400 | MPa | ISO 178 |
Flexural Modulus ¹¹ | 14260 | MPa | ASTM D790 |
Flexural Modulus ¹¹ | 13400 | MPa | ISO 178 |
Flexural Stress (Yield, at 2 mm/min) ¹¹ | 190 | MPa | ISO 178 |
Value | Units | Test Method / Conditions | |
Mold Shrinkage (on Tensile Bar, flow) ᵍ ¹¹ | 0.15 - 0.25 | % | SABIC method |
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹ | 0.2 | % | ASTM D955 |
Mold Shrinkage (flow, 24 hrs) ᵍ ¹¹ | 0.2 - 0.4 | % | ISO 294 |
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹ | 0.8 | % | ASTM D955 |
Mold Shrinkage (xflow, 24 hrs) ᵍ ¹¹ | 0.8 - 1.2 | % | ISO 294 |
Density ¹¹ | 1.65 | g/cm³ | ISO 1183 |
Density ¹¹ | 1.68 | g/cm³ | ASTM D792 |
Wear Factor Washer ¹¹ | 240 | 10^-10 in^5-min/ft-lb-hr | ASTM D3702 Modified: Manual |
Dynamic COF ¹¹ | 0.41 | - | ASTM D3702 Modified: Manual |
Static COF ¹¹ | 0.87 | - | ASTM D3702 Modified: Manual |
Value | Units | Test Method / Conditions | |
Coefficient of Thermal Expansion (at 23°C to 60°C, flow) ¹¹ | 0.000026 | 1/°C | ISO 11359-2 |
Heat Deflection Temperature/Af (at 1.8 Mpa, Flatw 80*10*4, sp=64mm) ¹¹ | 272 | °C | ISO 75/Af |
Relative Temperature Index (Electrical) ᵖ ¹¹ | 220 | °C | UL 746B |
Relative Temperature Index (Mechanical with impact) ᵖ ¹¹ | 200 | °C | UL 746B |
Relative Temperature Index (Mechanical without impact) ᵖ ¹¹ | 220 | °C | UL 746B |
Heat Deflection Temperature (at 1.82 MPa, 3.2mm, Unannealed) ¹¹ | 261 | °C | ASTM D648 |
Coefficient of Thermal Expansion (at -40°C to 40°C, flow) ¹¹ | 0.000026 | 1/°C | ISO 11359-2 |
Value | Units | Test Method / Conditions | |
Arc Resistance (Tungsten, PLC) ¹⁷ | 5 | PLC Code | ASTM D495 |
Comparative Tracking Index (UL, PLC) ¹⁷ | 4 | PLC Code | UL 746A |
Comparative Tracking Index (UL, PLC) ¹⁷ | 2 | PLC Code | UL 746A |
High Ampere Arc Ignition (PLC 4) ¹⁷ | min. 1.5 | mm | UL 746A |
High Voltage Arc Track Rate (PLC) ¹⁷ | 1 | PLC Code | UL 746A |
Hot Wire Ignition (PLC 0) ¹⁷ | min. 6 | mm | UL 746A |
Hot Wire Ignition (PLC 1) ¹⁷ | min. 3 | mm | UL 746A |
Hot Wire Ignition (PLC 2) ¹⁷ | min. 1.5 | mm | UL 746A |
Value | Units | Test Method / Conditions | |
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ | 21 | kJ/m² | ISO 180/1U |
Izod Impact (Unnotched, 80*10*4, at 23°C) ¹¹ | 45 | kJ/m² | ISO 180/1U |
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ | 9 | kJ/m² | ISO 180/1A |
Izod Impact (Notched, 80*10*4, at 23°C) ¹¹ | 6 | kJ/m² | ISO 180/1A |
Izod Impact (Unnotched, at 23°C) ¹¹ | 587 | J/m | ASTM D4812 |
Izod Impact (Notched, at 23°C) ¹¹ | 101 | J/m | ASTM D256 |
Value | Units | Test Method / Conditions | |
Drying Temperature ⁷ | 120 - 150 | °C | - |
Drying Time ⁷ | 4 | Hrs | - |
Melt Temperature ⁷ | 315 - 320 | °C | - |
Front - Zone 3 Temperature ⁷ | 330 - 345 | °C | - |
Middle - Zone 2 Temperature ⁷ | 320 - 330 | °C | - |
Rear - Zone 1 Temperature ⁷ | 305 - 315 | °C | - |
Mold Temperature ⁷ | 140 - 165 | °C | - |
Back Pressure ⁷ | 0.2 - 0.3 | MPa | - |
Screw Speed ⁷ | 30 - 60 | rpm | - |
Value | Units | Test Method / Conditions | |
UL Recognized (94-5VA Flame Class Rating) ᵖ | min. 3 | mm | UL 94 |
UL Recognized (94V-0 Flame Class Rating) ᵖ | min. 0.45 | mm | UL 94 |
Regulatory & Compliance
- Certifications & Compliance
Packaging & Availability
- Country Availability
- Regional Availability